Elektrmashinali kuchaytirgich (EMK) o’zgarmas tokda boshqarilishi va aylanish chastotasi yuklamaga bog’liq bo’lmagan ravishda o’zgarmas tokda ishlaydi.


EMK parametrlari quyidagicha: foydali quvvat P3N = 1300 W, chiqish kuchlanishi U3N = 230 V, aylanish tezligi nN = 4000 ayl/min, 15 ° C temperaturada cho’lg’am qarshiliklari : yakor cho’lg’ami RYa15 ° = 1.12 Om, kompensatsion cho’lg’ami
RK15 ° = 1.16 Om va boshqarish cho’lg’ami R1 15 ° = 4250 Om, kompensatsion cho’lg’am o’ramlar soni wK = 262 va boshqarish cho’lg’ami w1 = 4200, boshqarish cho’lg’ami toki i1 = 10 mA, bo’ylama λ = 790 ⋅ 10-8 va ko’ndalang λ = 200 ⋅ 10-8 o’qlar bo’yicha magnit o’tkazuvchanlik.
Quyidagilarni aniqlash kerak;
1. Kompensatsiya koeffitsientining uch xil qiymati KK = 0.99 ; 1,0; 1,01; uchun yuklama toki I3 0 dan nominalgacha I3N o’zgarganda EMK ning U3 = f (I3) tashqi xarakteristikasini hisoblang ;
2. Tokning nominal qiymati I3N va KK = 0,99; 1,0; 1,01; qiymatlar uchun kuchaytirish koeffitsienti KU ni aniqlash.
Yechish.
EMKning nominal toki.
I3H = P3H / U3H
EMKning chiqishdagi EYuKsi.
E10 = c · n2H · wK · i1
c =
Juft qutblar soni p = 1.
Yakor cho’lg’amining parallel o’tkazgichlar soni a = 1 ni tashkil qiladi.
Yakor cho’lg’amining o’ramlar soni - w1 = wK = 262.
Yakor cho’lg’amining o'tkazgichlar soni N = 4⋅a⋅w1 = 1048.
75 ° C temperaturada R1 va RYa qarshiliklari;
R = RЯ15º
R = RK15º
Ko’mir- grafit cho'tka uchun kuchlanish pasayishi; ΔUЩ = 2 V.
EMK ning chiqish kuchlanishi quyidagi formula bo'yicha hisoblanadi;
U1 = E30 - I3H ((RЯ + RK) – c· n2H · (wa - KK · wK )) - ΔUЩ
Hisoblashni kompensatsiya koeffitsientining uch xil qiymati KK = 0.99 ; 1,0; 1,01 uchun amalga oshiramiz;
KK= 0,99;
U1 = E30 - I3H ((RЯ + RK) – c· n2H · (w1 - KK · wK )) - ΔUЩ
KK= 1,0;
U1 =E30 - I3H (RЯ + RK) - ΔUЩ .
KK= 1,01;
U1 = E30 - I3H (RЯ + RK) - c· n2H · (w1 - KK · wK )) - ΔUЩ =
2. Kuchaytirish koeffitsienti chiqish quvvatining kirish quvvatiga nisbati quyidagi formula bilan aniqlanadi:
KУ =
Cho'tka kontaktlarining qarshiligi;
RЩ = ΔUЩ / I3H
K = 0,99; 1,0; 1,01; uchun U3 kuchlanishda yuklama qarshiligini hisoblanadi.
RH = U3 / I3H
RH = U3 / I3H
RH = U3 / I3H
K = 0,99; 1,0; 1,01. uchun qarshiliklar yigindisini aniqlanadi;
RΣ = RЯ + RK + RЩ
RΣ = RЯ + RK + RЩ.
RΣ = RЯ+ RK + RЩ
75 ° C temperaturada boshqarish cho’lg’ami qarshiligi;
R1 = R1 15º = 52,70 Оm.
K = 0,99; 1,0; 1,01. uchun kuchaytirish koeffitsienti hisoblanadi;
KУ =
KУ = =