Chapter 3 Measurement of Be-7 in Environmental Materials A. R. Iurian and G. E. Millward


Download 0.64 Mb.
Pdf ko'rish
bet4/19
Sana09.01.2022
Hajmi0.64 Mb.
#268006
1   2   3   4   5   6   7   8   9   ...   19
Bog'liq
Iurian-Millward2019 Chapter MeasurementOfBe-7InEnvironment

3.2.3

Samples of Rainwater

Samples of rainwater from the study site are required to assess the atmospheric

deposition flux of

7

Be during a period, encompassing the sampling campaign (see



Chap.

2

). The protocol for extraction of



7

Be from rainwater is presented in Appendix

2.1

.

7



Be can be pre-concentrated from solution by co-precipitation with MnO

2

following the method detailed by Short et al. (



2007

). The precipitate is recovered on

glass fibre filters which are placed in a Petri dish of suitable diameter and allowed

to dry before counting on an HPGe gamma detector.