Q = P
a
· K (1) 
Q = Pa · (tgφdastlabki - tgφtalab q.) (2) 
Pa = S · cosφdastlabki . (3)
tgφdastlabki= sinφdastlabk / cosφdastlabki (4) 
tgφtalab q. = sinφtalab q. / cosφtalab q. (5) 
Bu yerda Pa- aktiv quvvat (kvatt), K - jadvaldan olinadigan koeffitsient ,
S - to'la quvvat (kVA), Q - reaktiv quvvat (kVAR), cosφ - quvvat koeffitsenti 
jadval: K - koeffitsientini topish jadvali. 
Reaktiv quvvat kompensatorini 2 usulda hisoblab topishimiz mumkin. 
usul: 
Q = P
a
· K (1)-formula orqali hisoblab topamiz.


International Conference on Developments in Education, Sciences and Humanities 
Hosted from Hamburg, Germany 
httpseconferencezone.org 
 
May 4
th
 -5
th
 2022 
413
Reaktiv quvvat kompensiya qilish uchun kondendensator quvvatini hisoblashimiz uchun dastlab bizga 
berilgan ma`lumotlardan foydalanamiz. 
Agar aktiv quvvat berilmagan bo`lsa to`la quvvat S va quvvat koeffitsienti cosφtalab q. orqali (3)- formuladan 
hisoblab topamiz.
Pa = S · cosφdastlabki . (3) 
Keyin esa jadvaldan talab qilingan cosφtalab q. va dastlabki ya`ni elektr dvigatelining pasportidagi 
cosφdastlabki qiymatlaridan foydalanib K koeffitsientni topamiz va (1) - formula orqali hisoblaymiz. 
Q = Pa· K (1) 
usul:
Agar aktiv quvvat berilmagan bo`lsa to`la quvvat S va quvvat koeffitsienti cosφtalab q. orqali (3)- 
formuladan hisoblab topamiz. 
Pa = S · cosφdastlabki . (3) 
Keyin esa quvvat koeffitsientlari cosφdastlabki va cosφtalab q. dan foydalanib tgφdastlabki va tgφtalab q. (4) 
va (5) - formulalarga qo`yib hisoblaymiz va (2)- formuladan reaktiv quvvat kompensatsiya qilish uchun 
kondensator qurilmasini quvvatini hisoblab topamiz.
Q = Pa · (tgφdastlabki -tgφtalab q.) (2) 
Amaliy hisoblash uchun:
Elektr dvigatelning Aktiv quvvati Pa = 200 kVatt, Quvvat koeffitsienti cosφdastlabki = 0,6 . Reaktiv 
quvvatni kompensatsiya qilish uchun kondensatorning quvvatini hisoblab topamiz. 
Reaktiv quvvatni kompensatsiya qilish uchun cosφdastlabki ni qiymatini oshirishimiz kerak ya`ni cosφtalab 
q.=0.9 deb olamiz. 
- jadvaldan K koeffitsiyentni topamiz. K= 0,85 
Q = Pa· K = 200 x 0,85 = 170 kVAR 
Demak elektr dvigatel reaktiv quvvatini kompensatsiya qilish uchun quvvati Q=170 kVAR li kondensator 
qurilmasini o`rnatamiz. 
Foydalanilgan adabiyotlar: 
1. "Sanoat korxonalarining elektr tarmoqlarida reaktiv quvvat kompensatsiyasini loyihalash bo'yicha 
ko'rsatmalar" Zhelezko Yu.S. 
2. "Korxonalarning elektr tarmoqlarida reaktiv quvvat kompensatsiyasi uchun avtomatik qurilmalar" 
Krasnik V.V. 

Download 237.08 Kb.

Do'stlaringiz bilan baham:
1   2




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling