b) Zatvor kuchlanishining ta’sirini o’rganish
U
ZI
= -2.8 V
U
ZI
= -1.5 V
2-zanjir chizmasi
-
2-zanjir chizmasiga asosan zanjir yig’ing.
-
E kirish signali
manbaiga va A chiqish
signali nuqtasiga ossilografni ulang.
-
U
ZI
Zatvor kuchlanishini o’lchash
uchun
multimeterni ulang
-
Boshqaruv kuchlanishini 15
V qilib
o’rnating. Ulashda qutblarga e’tibor
bering.
-
Sinusoidal kirish signalini U
I
= 2 V va
f
= 1 kHz qilib tanlang.
-
U
ZI
kuchlanishini
U
ZI
=-10
V
potensiometr bilan o’rnating.
Ossilograf
bilan kirish va
chiqish signallari shaklini
kuzating.
-
U
ZI
zatvor kuchlanishini
chiqish signali
manfiy yarim davrga o’tmaguncha
kamaytiring.U
ZI
-ni o’lchang.
-
U
ZI
zatvor
kuchlanishini signal fazasi
musbat yarim davrga o’taboshlaguncha
kamaytiring. U
ZI
-ni o’lchang.
-
U
ZI
zatvor kuchlanishini 0 V ga
qo’ying. U
E,SS
va
U
A,SS
-kuchlanishlarni
o’lchang va (1) ga muofiq so’nish
koeffitsiyentini hisoblang.
O’lchash namunalari
a) Normal ochiq bo’lgan kanal
qarshiligini aniqlash
U
ZS
=
0
V
Y I: 2 V/ bo’linma DC
YII 2 V/ bo’linma
DC
Vaqt yoyilmasi 0.2
ms/bo’linma
■ Agar zatvor kuchlanishi -3 V< U
ZI
<-1.4
V oraliqda bo’lsa,
manfiy yarim davr
qirqqiladi(so’ndiriladi).Musbat
yarim
davr esa buzilmasdan o’tadi.
U
ZI
= -2.8 V
Y I: 2 V/ bo’linma DC
YII 2 V/ bo’linma
DC
Vaqt yoyilmasi 0.2
ms/bo’linma
Zatvor kuchlanishi U
ZI
<-1.4 V bo’lganida
signalning musbat yarim davri ham
■