Fourier Transform Infrared (ft-ir) Spectroscopy Theory and Applications
Intensity Distribution and Temperature Dependency versus Wavelength of Black Body Radiation Energy
Download 1.11 Mb.
|
FTIR-Presentazione pptx
- Bu sahifa navigatsiya:
- FT-IR Advantages
Intensity Distribution and Temperature Dependency versus Wavelength of Black Body Radiation Energy
2 5 20 10 105 104 103 102 10 1 10-1 10-2 10-3 10-4 0.1 0.2 0.5 1 50 100 Wavelength m 6000K 4000K 2000K 1000K 500K 300K 200K Spectral irradiance W IR light source IR Light Source FTIR seminar Interferometer He-Ne gas laser Fixed mirror Movable mirror Sample chamber Light source (ceramic) Detector (DLATGS) Beam splitter FT Optical System Diagram Fixed mirror B Movable mirror Fixed mirror A Movable mirror Fixed mirror C Movable mirror Same-phase interference wave shape Opposite-phase interference wave shape Same-phase interference wave shape 0 Movable mirror D Interference pattern of light manifested by the optical-path difference Continuous phase shift Signal strength I (X) -2 - 0 2 -2 - 0 2 FTIR seminar Interference of two beams of light Relationship between light source spectrum and the signal output from interferometer
light (b) Dichroic light spectrum light All intensities are standardized. Light source spectrum Signal output from interference wave Time t Time t Time t I(t) I Wavenumber Wavenumber Wavenumber I Az Az FTIR seminar Interference is a superpositioning of waves FTIR seminar Interferometer interferogram Output of a Laser interferometer Primary interferometer interferogram that was sampled Optical path difference x Sampling of an actual interferogram 4000 400 SB Fourier transform Optical path difference[x] (Interferogram) (Single beam spectrum) Wavenumber[cm-1] Single strength Time axis by FFT Wavenumber Fourier Transform FTIR seminar TGS Operates at room temperature MCT Operates at the temperatur of liquid nitrogen D* (, f) (cmHz1/2W-1) 1010 109 108 Wavenumber[cm-1] 4000 600 Detector Properties 1.Better sensitivity and brightness - Allows simultaneous measurement over the entire wavenumber range - Requires no slit device, making good use of the available beam 2.High wavenumber accuracy - Technique allows high speed sampling with the aid of laser light interference fringes - Requires no wavenumber correction - Provides wavenumber to an accuracy of 0.01 cm-1 3. Resolution - Provides spectra of high resolution 4. Stray light - Fourier Transform allows only interference signals to contribute to spectrum. Background light effects greatly lowers. - Allows selective handling of signals limiting intreference 5. Wavenumber range flexibility - Simple to alter the instrument wavenumber range CO2 and H2O sensitive FT-IR Advantages and Disadvantages FT-IR Advantages
FT-IR Advantages
FT-IR Advantages
Download 1.11 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling