In Vivo Dosimetry using Plastic Scintillation Detectors for External Beam Radiation Therapy
Download 2.07 Mb. Pdf ko'rish
|
In Vivo Dosimetry using Plastic Scintillation Detectors for Exter
Radiotherapy Patients in Panama, Report of a Team of Experts. International Atomic
Energy Agency, Vienna, Austria International Atomic Energy Agency 2001b. TRS 398 Report. Absorbed dose determination in external beam radiotherapy; an international code of practice for dosimetry based on standards of absorbed dose to water. International Atomic Energy Agency, Vienna, Austria. International Atomic Energy Agency 2013. Human Health Report No. 8. Development of procedures for in vivo dosimetry in radiotherapy. International Atomic Energy Agency, Vienna, Austria. International Commission on Radiological Protection 2000. ICRP Publication 86. Prevention of Accidental Exposures to Patients Undergoing Radiation Therapy. Elsevier Science. Jornet N, Carrasco P, Jurado D, Ruiz A, Eudaldo T, and Ribas M 2004 Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams. Med. Phys. 31 2534-42. Kertzscher G, Andersen CE, Tanderup K 2014. Adaptive error detection for HDR/PDR brachytherapy: Guidance for decision making during real-time in vivo point dosimetry. Med. Phys. 41 052102. 121 Klawikowski SJ, Zeringue C, Wootton LS, Ibbot GS, Beddar S 2014. Preliminary evaluation of the dosimetric accuracy of the in vivo plastic scintillation detector OARtrac system for prostate cancer treatments. Phys. Med. Biol. 59 N27-N36. Klein DM, Tailor RC, Archambault L, Wang LL, Therriault-Proulx F, Beddar AS 2010. Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors. Med. Phys. 37 5541-5549. Klein DM, Briere TM, Kudchadker R, Archambault L, Beaulieu L, Lee AK, Beddar AS 2012. In-phantom dose verification of prostate IMRT and VMAT deliveries using plastic scintillation detectors. Radiat. Meas. 47 921-929. Kulkarni PV, Antich PP, Anderson JA, Fernando J, Aminabhavi TM, Harlapur SF Aralaguppy MI, Balundgi RH 1997. Plastic scintillating materials in nuclear medical imaging. Polym.-Plast. Technol. Eng. 36 1-51. Lacroix F, Beddar AS, Guillot M, Beaulieu L, Gingras L 2009. A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization. 36 5214-5220. Lacroix F, Guillot M, McEwen M, Cojocaru C, Gingras L, Beddar AS, Beaulieu L 2010. Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector. Med. Phys. 37 4331-4342. Lambert J, Yin Y, McKenzie DR, Law S, Suchowerska N 2008. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide. Phys. Med. Biol. 53 3071-3080. 122 Liu PZY, Suchowerska N, Abolfathi P, McKenzie DR 2012. Real-time scintillation array dosimetry for radiotherapy: The advantages of photomultiplier detectors. Med. Phys. 39 1688-1695. Mackowiak PA, Wasserman S, Levine M 1992. A Critical Appraisal of 98.6 o F, the Upper Limit of the Normal Body Temperature, and Other Legacies of Carl Reinhold August Wunderlich. JAMA. 268 1578-1580. Mayles W 2007. The Glasgow Incident – a Physicist’s Reflections. Clinical Oncology. 19 4-7. Mijnheer B, Beddar AS, Izewska J, Reft C 2013. In vivo dosimetry in external beam radiotherapy. Med. Phys. 40 070903. Munro AJ 2007. Hidden danger, obvious opportunity: error and risk in the management of cancer. BJR. 80 955-966. Niroomand-Rad A, Blackwell CR, Coursey BM, Gall KP, Galvin JM, McLaughlin WL, Meigooni AS, Nath R, Rodgers JE, Soares CG 1998. Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. Med. Phys. 25 2093-2115. The Royal College of Radiologists, Society and College of Radiographers, Institute of Physics and Engineering in Medicine, National Patient Safety Agency, British Institute of Radiology 2008. Towards Safer Radiotherapy. The Royal College of Radiologists, London, UK. Rozman IM, Kilin SF 1960. Luminescence of Plastic Scintillators. Sov. Phys. Usp. 2 856- 873. 123 Saini A, Zhu T 2004. Dose rate and SDD dependence of commercially available diode detectors. Med. Phys. 31 914-924. Saini A, Zhu T 2007. Energy dependence of commercially available diode detectors for Download 2.07 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling