as insulated as the heating chamber. The surface of the door hood had a temperature of 80-
160°C for furnace 120 – 126. The area with high temperature was estimated to 3m² for each
furnace. If additional external insulation was attached to these high temperature areas, the
electricity consumption in the furnaces could be decreased. If, for example, a 0.08m thick
insulation weave was attached to the hoods on all main furnaces in the large line, the energy
consumption in these furnaces would decrease with 108.7 MWh/year. See section 2.6 for the
equations used for these calculations.