4.5.5 District Heating
The current consumption of district heating in the plant is 120 MWh/year. Even though the
consumption would be 382 MWh/year if a planned investment is not made, all calculations
are based on a consumption of 120 MWh/year. However, the percentages for case III in table
10 are based on a total consumption of 382 MWh/year. The reason for this is that the
investment for reducing the district heating demand is included in this scenario.
Another district heating price is used for case III for the calculation of the annual savings for
this scenario. Since this scenario includes the reduction of the district heating demand, the
annual cost savings for removing the remaining district heating demand by heat exchanging
the waste heat from the compressor is based on a lower district heating price. This is because
the district heating price would decrease if the total demand was reduced. The price would
decrease because a part of the tariff is based on the highest load during the previous year.
25
5 Results
The results from the energy audit are presented in this chapter. First is a description of the
current energy consumption distribution in the plant. The next sections present the possible
energy saving measures that have been investigated during the project. The last part of this
chapter includes the results from the evaluation of these suggestions.