Only admistrator


Download 445 b.
Sana21.07.2018
Hajmi445 b.





ONLY ADMISTRATOR

  • ONLY ADMISTRATOR

  • The Chief Executive has the signature and represent the company before third parties and in court, with power to take action, and the judicial and administrative procedures, as well as to reach agreements and compromise.

  • The Chief Executive has the broadest powers and fulfills the duties that are imposed by law and articles of association and is responsible to society from damage caused by disregard of such duties.

  • Supervise general business management so that there are no acts detrimental.

  • Is responsible for all the functions necessary for the general conduct of the Company, both from an administrative, commercial and technical including the coordination and supervision of the application of safety standards, health physics, quality assurance, including the activities of in-service inspection, etc.



TECHINCAL DIRECTOR & COMMERCIAL

  • TECHINCAL DIRECTOR & COMMERCIAL

  • The technical director & commercial, is responsible for leading the company's technical and commercial contacts with customers, in their work schedules.

  • program phases of work with evaluation of personnel and equipment to be used;

  • supervising the various phases of work being careful that all NDT take place in accordance with the provisions in the PO and IT;

  • is responsible, in conjunction with the Department, the policy of applying new techniques and research program and feasible special controls;

  • intervenes actively in the approval of safety programs and health physics;

  • defines and documents the objectives of the quality policy (operational) that the Company is committed to achieve and maintain, through the distribution of Operating Procedures (PO), which he edited and continuously updated and revised;

  • manages the Work Progress while monitoring both the financial report (for the company) and the quality and quantity of controls (for the customer);

  • has the responsibility to resolve N.C. of the product.



QUALITY MANAGER

  • QUALITY MANAGER

  • The quality manager must define, control, implement and assess the adequacy of the system of quality management, his having been given the authority and the freedom they need, both for the conduct of the above, is to promote corrective action.

  • defines and documents the objectives of the quality policy that the company is committed to achieve and maintain, through the distribution of MQ and PQ he drafted and continuously updated and revised;

  • provides training and indoctrination of personnel and functions directly responsible for the company's quality;

  • qualifying suppliers and products which they purchase;

  • manage and calibration and / or maintenance of control equipment;

  • manages all the documents concerning the quality ensuring adequate records;

  • maintains relationships with external inspection bodies;

  • together with the project manager, and then provides the processing, approval of the various plans of contract and subsequent amendments and revisions, also providing, monitoring of the activities planned in the same planes of order.



SAFETY MANAGER PHYSICAL - R.S.P.P.

  • SAFETY MANAGER PHYSICAL - R.S.P.P.

  • The head of security, is the interface of the company with the qualified expert for physical, and with a licensed physician for medical surveillance.

  • In particular making use of consultants listed above, must :

  • issue and update the manual safety, both on accident prevention, is inherent in detention, use and transport of radioactive isotopes and X-ray equipment;

  • issuing and updating procedures of operation, in terms of security, of different equipment supplied;

  • keep updated the book accidents and provide for prescribed complaints and communications;

  • keep the register of loading and unloading sources and provide for the procurement of communications, navigation and deliver knowledge;

  • maintain contacts with the authorities responsible for the handling of all matters concerning the transportation, possession and use of X-ray equipment;

  • provide to perform the medical examination of employment, periodic and termination benefits work;

  • supervise any work in order to ensure that personnel training, dating means, correct procedures, etc. they allow the execution in the best conditions of safety;

  • provides training and indoctrination of the staff and managers of the safety in the workplace.





CORPORATE STRUCTURE



1_LEGAL STRUCTURE

  • 1_LEGAL STRUCTURE

  •  

  • Corporate name : SICIL SERVICE CND S.r.l. / Year of Constitution : Settembre 1993

  • Registered Head Office : Via A. Gramsci, 6 Pal. B1 – 98057 – Milazzo (Me)

  • Share Capital : € 51.480,00 (£ 99.000.000) i.v.

  • Position INPS : 4805131561 Position INAIL : 8376902/71

  • C.C.I.A.A. : Messina n° 147816

  • Iscr. Canc. Trib. : Barcellona P.G. (Me) n° 43986/9741

  • Fiscal Code e Var Number : 01822710834



  • Administrative Office : Via A. Gramsci, 6 Pal. B1 (Piano 2°) – 98057 – Milazzo (Me) – Tel. +39 090 922 15 35 – Fax +39 090 928 51 05

  • area_amministativa@sicilservicecnd.it

  • Technical Office : Via A. Gramsci, 6 Pal. B1 (Piano 1°) – 98057 – Milazzo (Me) – Tel. +39 090 924 01 64 – Fax +39 090 924 14 69

  • area_tecnica@sicilservicecnd.it

  • Detached site Napoli : Via Dante Alighieri n° 18 – 80010 – Quarto (Na) –Tel./Fax +39 081 8767091

  • cantierenapoli@sicilservicecnd.it

  • Detached site Gela : I° Traversa Zona Industriale – 93012 – Gela (Cl) –Tel. +39 3314829195 - +39 3351084824

  • cantieregela@sicilservicecnd.it

  • Detached site Priolo Gargallo : c/o ISAB srl ex ss114 km 146 – 96010 – Priolo Gargallo (SR) – Tel. +39 3357254236

  • cantiereisab@sicilservicecnd.it



2_BUSINESS SEGMENTS '(CND, INSPECTION, TESTING AND CERTIFICATION)

  • 2_BUSINESS SEGMENTS '(CND, INSPECTION, TESTING AND CERTIFICATION)

  • The Sicil Service is a service company specializing in non-destructive testing.

  • The control methods used are: radiographic Selenium-XY, liquid penetrant, magnetic particle, ultrasonic thickness with using professional scaffolding or mobile platform, ultrasound defectoscopic, chemical analysis, thermography, endoscopy, radiography digitized, leak tests, surveys with laser scanner technology 3D, Gas Find-IR, Phased Array, TOFD, induced current, vacuum box.

  • The business has expanded over the execution of heat treatment on piping welds and metal components, also to the management of the data base for inspections of plants (CREDO, SAP, MERIDIUM).

  • The Sicil Service has always worked in all industries, especially in the petrochemical and power generation.



The Sicil Service has always worked in all industries, especially in the petrochemical and power generation.

  • The Sicil Service has always worked in all industries, especially in the petrochemical and power generation.

  • The team can intervene in the preparation and planning of the program of checks stop, during the stop for the controls and during the year for the completion of all paperwork regarding the approval by ISPESL of equipments and lines that have undergone repairs and / or modifications.

  • Depending on the type of plant and the related issues of corrosion, it puts up a detailed list of inspection activities of maintenance and CND (ultrasound, radiography, liquid penetrant, magnetic particle, heat treatment etc.) to be implemented in the plant shutdown.

  • During the stop of the plant performing visual inspections and NDT programmed, are evaluated all the problems encountered, the remedies to be taken during the stop and those to be programmed for the next general shutdown of TA.



  • The remedies are well evaluated with the objective of cost-benefit and may also result in changes of metallurgy, process offsets, use of corrosion inhibitors, changes of pressure vessels and piping etc. Provide assistance for the verification of law (ISPESL / INAIL and ASP) supplemented, if necessary, by stability calculations.

  • A stop end is preparing the inspection report on which will be reported in detail all the inspection findings, the drawbacks, the remedies adopted and program, arrangement etc. at the request of the Client, you can transfer the elaborate inspection on suitable supports.

  • Running the "Table of Complaint" to be presented to ISPESL piping within the scope of Article. 16 of DM 01/12/2004 n ° 329/2004.

  • Execution for the technical report for each individual line in the of the plant and / or dell'interconnecting for the periodic retraining pursuant to Art. 16 of 329 DM.

  • Preparation of all reports to be submitted to the redevelopment officials ISPESL / INAIL and ASP.



3_CERTIFICATION AND QUALIFICATIONS

  • 3_CERTIFICATION AND QUALIFICATIONS

  • The Sicil Service applies a quality system complies with the requirements of UNI EN ISO 9001: 2008 in all activities, in fulfillment of the provisions of the regulations / applicable codes and / or technical specifications provided for the purpose.

  •  

  • The Sicil Service is also in possession of the certification service provider for ships "SERVICE SUPPLIERS" for running ndt, issued by RINA GROUP Office of Messina.

  • The Sicil Service is also qualified at the following companies :

  • Enel – Edison – A2A – ENI – Snam Rete Gas – Raffineria di Milazzo – Isab – Saipem.





4_TECHNICAL REQUIREMENTS

  • 4_TECHNICAL REQUIREMENTS

  •  

  • The Sicil Service has a staff of qualified according to the UNI EN ISO 9712 and SNT-TC-1A and approved by Recognized Third Entity in accordance with the requirement of paragraph 3.1.3. Annex I of Directive 97/23 / EC (PED) regarding the pressure equipment and with many years of experience in the field of non-destructive testing. It is also in possession of the permits prefectural for the execution of radiographic throughout Italy and the ministerial authorization road transport of radioactive materials. The Company also owns a mobile radiographic laboratory. The Sicil Service over the execution of non-destructive testing is able to study and develop innovative procedures aimed at solving specific problems of corrosion and metallurgical.

  • The Sicil Service collaborates, for several years, with the Quality Control for the 'execution and certification of laboratory tests (mechanical tests, metallographic, corrosion, estensiometriche) on metallic materials.



5_TECHNICAL PERSONNEL 

  • 5_TECHNICAL PERSONNEL 

  • Administrative Employees: n° 5

  • Engineers : n° 3

  • Foremen : n° 3

  • Qualified Operators Level 3 UNI EN ISO 9712 : n° 2

  • Qualified Operators Level 2 UNI EN ISO 9712 : n° 43

  • Qualified Operators Level 3 ASNT–TC–1A : n° 1

  • Qualified Operators Level 2 ASNT–TC–1A : n° 10

  • Operators Experts in Heat Treatments : n° 6

  • Operators Experts in Chemical Analysis of Materials(PMI) : n° 4

  • Operators experts in survey Sketch : n° 6

  • Computer Operators for the Computer-based Management of Inspections : n° 7

  • Inspectors of Plants for Inspections : n° 7

  • Inspectors of plants Inspections Lines : n° 7

  • External Consultants: n° 3



6_EQUIPMENTS AND VEHICLES

  • 6_EQUIPMENTS AND VEHICLES

  • X-RAY EQUIPMENT: n° 5

  • GAMMAGRAPHIC RY EQUIPMENT : n° 11 (fino a 100 Ci)

  • GAMMAGRAPHIC RY EQUIPMENT (Selenium) : n°1 (fino a 150 Ci)

  • ULTRASOUND DEVICES THICKNESS: n° 20

  • ULTRASOUND DEVICES DEFECTOSCOPIC : n° 6

  • EQUIPMENT MAGNETOSCOPIC: n° 9

  • ANALYSERS ALLOYS FOR CHEMICAL ANALYSIS SPECTROMETER : n° 2

  • DUROMETER PORTABLE KRAUTKRAMER Mic 10DL

  • MACHINES HEAT TREATMENT : n° 12

  • MACHINES THERMOGRAPHIC INFRARED: n° 3

  • - Thermographic Camera Mod. P M 575 Flir Systems;

  • - Thermographic Camera Mod. P 620 Flir Systems;

  • Thermographic Camera Mod. E 45 Flir Systems;

  • Thermographic Camera Gas Find IR Mod. GF320 Flir Systems.



SYSTEM DIGITAL RADIOGRAPHY KODAK INDUSTREX : n° 1

  • SYSTEM DIGITAL RADIOGRAPHY KODAK INDUSTREX : n° 1

  • - Digital processor Kodak ACR – 2001 i

  • - Digitization System Films (archive) Kodak LS 85

  • VIDEOENDOSCOPE OLYMPUS Iplex 2 BASIC-R : n° 1

  • VIDEOENDOSCOPE (other brands): n° 2

  • BOXES FOR VACUUM BOX AND VACUUM PUMPS : n° 2

  • PRECAST BOX FOR DARK ROOM OR OFFICE : n° 7

  • VEHICLES AUTHORIZED TO TRANSPORT OF RADIOACTIVE SOURCES : n° 9

  • VEHICLES VANS : n° 10

  • VEHICLE SERVICE : n° 10

  • GENERATOR TENSION 380/220 V DA 135 KV : n° 1

  • GENERATOR TENSION 380/220V DA 6 KV : n° 3



7_PRINCIPAL CLIENTS

  • 7_PRINCIPAL CLIENTS

  • Raffineria di Milazzo ScpA - ENI SpA - Centro Ricerche ENI - Edipower Centrale San Filippo del Mela (Me) - Snam - Ansaldo Energia - Ansaldo Caldaie - Saipem - Trio Srl - Coop. Sicem - Linde S.p.A. - Turbotecnica - Isab Energy – Termokimik - Demont - Irem - Edison SpA - Isab - Techint - Technip - Sonim - A2A - General Construction - Energia Molise (Termoli) - Tirreno Power (Na) - Cosmi SpA (Ravenna) - Emerson Network Power - Lukoil (Siracusa) - GEKO S.p.a. – EXXON Mobil.



8_PRINCIPAL SUPPLIERS

  • 8_PRINCIPAL SUPPLIERS

  • Semat – Gilardoni - Gammaind - Sicort - Panametrics – Krautkramer - NDT - Sirio Ultrasuoni - Ades NDT - Dimart - Flir Systems - ADG Srl - ADG gamma technologies - Smart NDT - IMG – Casoni – TQ Srl.



9_OUR PARTNERS

  • 9_OUR PARTNERS

  • The Sicil Service owns 95% of the company's non-destructive "EURO GLOBAL SERVICE Srl" based in Sibiu-ROMANIA

  •  Also works for individual specific activities with international companies listed below:

  • VERKADE N.D.T. SERVICES GmbH – Germany

    • Hydrogen Induced Cracking of research (Stepwise Cracking) in equipment subject to the presence of wet H2S.
    • UTD semi-automated checks for corrosion research on media lines system.
  • MISTRAS GROUP– Netherlands

  • Acoustic Emission method Tankpac Monpac or control funds for storage tanks

  • RIT (Rosen Inspection Technologies) – Netherlands

  • Control funds tanks - method Floor Scan and control with pig-intelligent method RoCorrUT lines underground and not buried.



EC-WORKS GmbH – Germany

  • EC-WORKS GmbH – Germany

  • Eddy Current Controls and ultrasonic IRIS tubes of heat exchangers

  • SONOVATION – Netherlands

  • Automated ultrasonic inspections - method TOFD, phased array and P-scan control even at high temperature.

  • UT-QUALITY – Netherlands

  • UTD AUT on pipeline construction and control with TOFD, Phased Array Ultrasonics (The mostadvanced Phased Array Technology for Boiler Tube Inspection) on pipes of small diameter coils or wall construction of the Central boiler plants.

  • QUALITY CONTROL – Italy (Test Laboratory certified by ACCREDIA)

  • Laboratory tests on welded joints and metal materials - Mechanical Tests, Tests Metallographic, Corrosion Testing, Testing Estensiometriche



10_LIST OF PROJECTS COMPLETED AND IN PROGRESS

  • 10_LIST OF PROJECTS COMPLETED AND IN PROGRESS

  • RAM Raffineria di Milazzo

  •  1999-2016 - Open order for NDT, heat treatment and inspection systems, Automated Management of Inspections and Ge.ISPE CREDOSoft

  •  1993-2016 - NDT and heat treatments on plants in maintenance or in construction

  • 2010-2016 - Order framework QM quality control warehouse

  • EDISON Centrali Area Sud Italia

  •  2013-2016 - Open order for NDT, heat treatment and inspection systems various

  • ISAB Impianti Priolo

  • 2011- 2013 - Specific order NDT inspections and T / A

  • 2011-2014 - Open order for NDT and inspection

  • 2012-2016 - Open order for controls specialist H2S- wet

  • LINDE Impianto Milazzo

  • 2011- 2014 - Specific order and NDT inspections



ENEL/EDIPOWER

  • ENEL/EDIPOWER

  • 1994-2000 - Open order ENEL Milazzo for NDT and heat treatments on plants under construction and adaptation Desox / Denox

  • 2005-2015 - Open order for NDT, heat treatment and inspection systems

  • SNAM 

  • 1995-2008 - Non Destructive Testing of bedrooms and pipelines connecting towns in the province of Agrigento, Catania, Messina and Syracuse, and insertion of insulating joints line DN 48 "pipeline's Mediterranean province of Messina

  • SICILIANA GAS 

  • 1995-2011 - Open order for NDT on parts of plants (lines and bedrooms) - Sicily Region  

  • GAS S.p.A./ NATURAL GAS 

  • 2000-2016 - Open order for NDT on parts of plants (lines and bedrooms) - Sicily Region  

  • CENTRALE DI TERMOUTILIZZAZIONE RIFIUTI URBANI DI PIACENZA

  •  2002-2003 - NDT and heat treatment of piping welds thermal cycle

  • 2006-2014 - Open order for NDT



RAFFINERIA TAMOIL DI CREMONA 

  • RAFFINERIA TAMOIL DI CREMONA 

  • 2003-2005 - Open order for NDT, heat treatment and inspection systems.

  • 2010-2013 - Open order for NDT, heat treatment and inspection systems.

  • FISIA – TERMOVALORIZZATORE ACERRA (Na) 

  • 2006-2010 - NDT and heat treatment on the building facility.

  • CENTRALE TERMOELETTRICA SPARANISE (Ce)

  • 2011-2016 - Open order (GE.CO) NDT and inspection systems for various

  • GEKO S.p.a.

  • 2016-2019 - Open order NDT for thermal power plants SPARANISE (Ce) e RIZZICONI (Rc)

  • CONSTRUCTION OF POWER STATIONS– NDT and Heat Treatments

  •  ENIPOWER FERRERA ERBOGNONE 2003

  •  VOGHERA ENERGIA 2004 

  • ENERGIA MOLISE – CENTRALE A CICLO COMBINATO TERMOLI 2005

  • ANSALDO/GE.CO - CENTRALE TERMOELETTRICA SPARANISE (Ce) 2006-2007



CENTRALE TERMOELETTRICA SPARANISE (Ce) 2009-2010

  • CENTRALE TERMOELETTRICA SPARANISE (Ce) 2009-2010

  • TECHINT / INTAS – CENTRALE TERMOELETTRICA COGENERATIVA SCANDALE (KR) 2007-2008

  • ABRUZZO ENERGIA SpA / GRUPPO COSMI – CENTRALE A CICLO COMBINATO GISSI (Chieti) 2007-2008

  • ANSALDO/GE.CO-CENTRALE TERMOELETTRICA A CICLO COMBINATO TURANO LODIGIANO( LODI ) 2009-2011

  • ANSALDO/GE.CO-CENTRALE TERMOELETTRICA A CICLO COMBINATO SAN SEVERO (FOGGIA) 2009-2011






Do'stlaringiz bilan baham:


Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2017
ma'muriyatiga murojaat qiling