Li et al. / Building Simulation / Vol. 13, No. 3
579
Table 2
Optical properties of the glass
panes in the comparative
simulation cases
Glass type
Clear glass
(PLANILUX_6)
Low-e coated glass
(PLANITHERM
ONE 2)
Thickness (m)
0.0059
0.006
Solar transmittance at normal
incidence
0.806 0.489
Solar
reflectance at normal
incidence (front side)
0.072 0.390
Solar reflectance at normal
incidence (back side)
0.071 0.447
Emissivity (front side)
0.84
0.84
Emissivity (back side)
0.84
0.022
(
f2) is taken the same as ambient temperature,
based on the
assumption of thorough heat transfer with municipal feed
water at the tank. For
Cir2, the flowing water layer (
f5)
releases heat to the room space
during heating season and
collects solar thermal energy in the remaining seasons.
Therefore, the inlet temperature of the internal water layer
(
f5) is higher than
indoor air in heating season, which
includes January, February and December for Shenzhen.
In order to evaluate the influence
of water temperature on
system energy and economic performance,
the inlet tem-
peratures of the internal water layer (
f5) is set to be 34 °C in
Case 2, 37 °C in Case 3 and 40 °C in Case 4
. In the remaining
period, the inlet
water temperature of f5 is set the same as
ambient temperature.