6. Steam Stop Valve. It regulates the flow of steam supply outside. The steam from the boiler
first enters into an ant-priming pipe where most of the water particles associated with steam are re- moved. 7. Feed Check Valve. The high pressure feed water is supplied to the boiler through this valve. This valve opens towards the boiler only and feeds the water to the boiler. If the feed water pressure is less than the boiler steam pressure then this valve remains closed and prevents the back flow of steam through the valve. STEAM GENERATOR 183 Water Steam Fire and hot gases Air in Ash-pit Grate Fire Box Fire Tubes Water Steam Steam stop valve Pressure gauge Manhole Feed check valve Water in Water level indicator Fusible plug Combustion Chamber Fire brick lining Blow off cock Mud and water out during blow off Boiler shell Fire door Smoke Box Doors Chimney Anti priming pipe Dead Weight Safety Valve Steam out Fig. 5.1. Cochran Boiler. 5.4 LANCASHIRE BOILER It is stationary fire tube, internally fired, horizontal, natural circulation boiler. This is a widely used boiler because of its good steaming quality and its ability to burn coal of inferior quality. These boilers have a cylindrical shell 2 m in diameters and its length varies from 8 m to 10 m. It has two large internal flue tubes having diameter between 80 cm to 100 cm in which the grate is situated. This boiler is set in brickwork forming external flue so that the external part of the shell forms part of the heating surface. The main features of the Lancashire boiler with its brickwork shelling are shown in figure. The boiler consists of a cylindrical shell and two big furnace tubes pass right through this. The brick setting forms one bottom flue and two side flues. Both the flue tubes, which carry hot gases, lay below the water level as shown in the Fig. 5.2. The grates are provided at the front end of the main flue tubes of the boiler and the coal is fed to the grates through the fire doors. A low firebrick bridge is provided at the end of the grate, as shown in the Fig. 5.2, to prevent the flow of coal and ash particles into the interior of the furnace tubes. Otherwise, the ash and coal particles carried with gases form deposits on the interior of the tubes and prevent the heat transfer to the water. The firebrick bridge also helps in deflecting the hot gases upward to provide better heat transfer: 184 POWER PLANT ENGINEERING Wa te r i n S u pe rh ea te d s te am o ut Wa te r ou t Ec o n o m is e r L o w wa te r s a fe ty v a lv e St e a m st o p va lve M a in h o le S hel l Sa fe ty va lve Fu s ib le pl ug Fi re h o le A A Fi re B ri d g e B o tt om F lu e F u rn ac e t u be 1 2 Gr a te Blow of cock 2 2 Bo tt o m fl ue Side flues Da m p e rs E x ha us t t o C h im n e y Wa te r St e a m H o t Ga s e s Download 3.45 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling