3.2-Masala
Ampermetr, voltmetr va vattmetrlar transformasiya koeffisentlari KI=60 va KU=10 ga teng bo’lgan tok va kuchlanish transformatorlari orqali bir fazali o’zgaruvchan tok tarmog’iga ulangan. O’lchash asboblarining, zanjirdagi tok kuchi, kuchlanish va quvvatni ko’rsatishlari IA=3 A, UV=90V va PW=150 Vt ga teng bo’lsa aniqlang.
Yechilishi:
Zanjirdagi tok kuchini aniqlaymiz:
I=KT·IA=60·3=180 A.
Zanjirdagi kuchlanishni aniqlaymiz:
U=KH·UV=10·90=900 B.
3. Zanjirdagi aktiv quvvatni quyidagicha aniqlaymiz:
P=KT·KH·PW=60·10·150=90000 Вт =90 кВт.
3.3-Masala
Elektromagnit tizimdagi voltmetrning ichki qarshiligi RV=20 k Om , nominal kuchlanishi Un=380 V bo’lsa, voltmetrning ulchash chegarasini U=600 V ga oshirish uchun kerak bo’ladigan kushimcha qarshilikni qiymati RK ni aniqlang va ulanish sxemasini chizing.
Yechilishi:
Kushimcha qarshilikdagi kuchlanishlar pasayishini xisoblaymiz.
Uk=U-Unom=600-380=220 V
Voltmetrdan oqib utadigan tokni xisoblab topamiz: Iv=Un/rv=19 mA.
Kushimcha qarshilikni mikdorini aniqlaymiz:
Rк=Uк/Iv=11,6 кОм
3.4-Masala
Ichki qarshiliklari r01=20 kOm va r02=24 kOm bo’lgan ikkita voltmetrlar ketma-ket ulangan. Agar ular umumiy kuchlanishi vq600 V ga ulansa. Agar voltmetrlari shkalalari mos ravishda v1tok=300 V xamda v2njr=400 V bo’lsa. ularni ko’rsatishlari qanday miqdorda bo'ladi
3.5-Masala
Ekvivalentning qarshiligi aniklansin
3.6-Masala
120 V kuchlanishga mo’ljallangan qarshiligi 240 Om bo’lgan elektr lampani 220 V kuchlanishli tarmoqga ulash lozim. Buning uchun kesimi 0,55 mm2 bo’lgan nixrom o’tkazgichdan necha metr olib lampochkaga ketma-ket qilib ulash kerak?