An887, ac induction Motor Fundamentals


FIGURE 18: TORQUE-SPEED CURVES OF DIFFERENT NEMA STANDARD MOTORS


Download 427.13 Kb.
Pdf ko'rish
bet16/30
Sana25.08.2023
Hajmi427.13 Kb.
#1670162
1   ...   12   13   14   15   16   17   18   19   ...   30
Bog'liq
00887a

FIGURE 18:
TORQUE-SPEED CURVES OF DIFFERENT NEMA STANDARD MOTORS
Design B
Design C
Design D
Design A
20
40
60
80
100
Speed (%)
T
o
rqu
e
 (%
 of F
u
ll-Lo
ad T
o
rq
ue)
300
200
100


AN887
DS00887A-page 12

2003 Microchip Technology Inc.
Recently, NEMA has added one more design –
Design E – in its standard for the induction motor.
Design E is similar to Design B, but has a higher
efficiency, high starting currents and lower full-load
running currents. The torque characteristics of Design
E are similar to IEC metric motors of similar power
parameters.
The IEC Torque-Speed Design Ratings practically
mirror those of NEMA. The IEC Design N motors are
similar to NEMA Design B motors, the most common
motors for industrial applications. The IEC Design H
motors are nearly identical to NEMA Design C motors.
There is no specific IEC equivalent to the NEMA
Design D motor. The IEC Duty Cycle Ratings are
different from those of NEMA’s. Where NEMA usually
specifies continuous, intermittent or special duty
(typically expressed in minutes), the IEC uses nine
different duty cycle designations (IEC 34 -1).
The standards, shown in Table 1, apart from specifying
motor operating parameters and duty cycles, also
specify temperature rise (insulation class), frame size
(physical dimension of the motor), enclosure type,
service factor and so on.
TABLE 1:
MOTOR DUTY CYCLE TYPES AS PER IEC STANDARDS
No.
Ref.
Duty Cycle Type

Download 427.13 Kb.

Do'stlaringiz bilan baham:
1   ...   12   13   14   15   16   17   18   19   ...   30




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling