User Manual


How to set up model parameters using diagram ?


Download 1.11 Mb.
Pdf ko'rish
bet16/25
Sana18.02.2023
Hajmi1.11 Mb.
#1211799
1   ...   12   13   14   15   16   17   18   19   ...   25
Bog'liq
Inor.XL

How to set up model parameters using diagram ? 
All parameters of object in diagram can be split up on two groups. The first group is for geome-
try, view mode and interconnection of objects. Second group consists of model parameters, which are 
connected to tabular model data in Excel. For selected object parameter set will be shown in context 
panel. Buses, branches, transformers, generators, reactors and compensators have its individual context 
panel. So graphics can not only create and view diagrams, but also makes possible to create full model 
data set. 
Users can choose appropriate way for model creation. If one has tabular data, graphics helps to 
create diagram easily, by reusing tabular data. After successful load flow all parameter values will be 
transferred to diagram and shown on it. If user has no tabular data, it can be easier to draw diagram 
with graphics, supplying model data by accessing graphical objects properties. 
Beta versions have diagram-table transfer temporarily disabled 
Consider example of use context panel for bus. To access panel select some bus in diagram.
The whole parameter set is shown on panel. One can enter load power values: 


19 
and then, power of generation at bus: 
then, reactor conductance value for inductive compensation 
or capacitive compensation 


20 
As you can see graphical representation of bus reflects parameters entered with context panel. 
In addition, any connected to bus object can be edited individually. At the picture below there is genera-
tor context panel, available for selected generator object. 
All tabular data is transferred to diagram on each load flow calculation. Also all parameters can 
also be edited in tabular representation. You can see calculated load flows on branches and voltages at 
bus at the pictures above. Please note, that all texts have white contours around, to clarify representa-
tion in case of object overlays.
Generator, reactor and load primitives are placed at bus automatically. Text blocks can be 
placed manually, but after bus rotation text blocks will be rearranged again. Bus moving does not cause 
any rearrangements of bus dependent objects. 