Heat flow rate: 
The heat flow rate Q can be calculated as [35] 

)
-----------------------------------------------------------------------3.21 
Where 
 
H is the amount heat flow (input power)in material Mcal/hour,
 
Q is the flow rate of heat through array of nozzles to glass surface by 
compressed air (radiation and convention)
 
 is density of air
 
 
 is the specific heat of air, Mcal / deg .ton, 
 
is heating temperature 
 
is lower temp/room temperature
The required amount of heat flow (input power) H can be calculated as 
1. By conduction [36] 
Rate of heat conduction ∞ 
( )( )
---------------------------------------------------------------------------------------3.22 
Where,
 
(
)is is the thermal conductivity of the glass 
 
( ) Thickness of the glass and furnace chamber that has physical
contact to the heater
Thus
2. By convention and radiation 


Fuzzy PID Based Temperature Control of Electric Furnace for Glass Tempering Process
M.Sc. Thesis, Addis Ababa University, December 2016 
30 
By radiation heat transfer to or from a surface surrounded by a gas such as air occurs parallel 
to conduction (or convection, if there is bulk gas motion) between the surface and the gas [36]. 
Thus the total heat transfer is determined by adding the contributions of both heat transfer 
mechanisms. For simplicity and convenience, this is often done by defining a combined heat 
transfer coefficient
that includes the effects of both convection and radiation 

)--------------------------------------------------------3.23 
Where,
 

)
 
is surface temperature and ( 
) is temperature of the gas. 
 
is surface area of the glass to be heated. 
Thus
60,616.6 watt 
Therefore total amount of heat transfer is
-----------------------------------------------------------3.24 
Assumptions 

volume of the furnace chamber is chosen to be V=4m^3 

velocity of the glass is chosen to be

Length of furnace =2m 
=0.18 cal/gram
o

=2.5gram/cm^3 
Electric Power =120kw=120kJ/s 
Thus substituting in Eq.(3.21)
Q= 0.16m^3/s 
Substituting the values of Q , V,
in Eq.(3.5) yields: 


Fuzzy PID Based Temperature Control of Electric Furnace for Glass Tempering Process
M.Sc. Thesis, Addis Ababa University, December 2016 
31 
K=13.07 and 
T=25s
And the delay time
=20s 
Thus the dynamic model of glass tempering resistance furnace is 
( )
( )
( )
----------
------------------------------------------3.25