MSA 2060 Technical Specifications
Power requirements
Input Power Requirements (typical-running I/O)
SFF/LFF arrays
120VAC 3.07A, 293-361 W; 220VAC 1.58A,289-
352W
Max Input Power
100-240 VAC, 50/60 Hz., 4.38-2.17A; 48-60 VDC
10.4A/8.3A
Heat Dissipation
1766 BTU/hr
Temperature and Humidity Ranges
Operating
Temperature
ASHRAE A3 5°C to 40°C, -12°C DP & 8 to 24°C DP
(Derate maximum allowable dry-bulb temperature
1°C/175m above 900m)
Shipping Temperature
-40°F to 158°F (-40°C to 70°C)
Operating Humidity
Up to 85% RH
Non-Operating Humidity
Up to 90% RH @ 30°C
Physical
Height
3.5 in (8.9 cm)
Depth (Back of chassis ear to controller latch)
20.0 in (50.8 cm)
Depth (Front of chassis ear to back of cable bend)
26.4 in (66.9 cm)
Width (Chassis only)
17.5 in (44.5 cm)
Width (Chassis with bezel ear caps)
19.0 in (48.3 cm)