Instructions for use [ operation manual ] I ■ Please read through the introduction before use to


GB20©,DU 14®,GB21 ©, SI 11© ,EX-HN 15©,LI 15©


Download 259.37 Kb.
bet7/7
Sana08.01.2022
Hajmi259.37 Kb.
#240761
TuriInstructions
1   2   3   4   5   6   7
Bog'liq
Untitled

GB20©,DU 14®,GB21 ©, SI 11© ,EX-HN 15©,LI 15©

Stiff neck

GB20©, BL 10©. ST25®, L115©, SJ5©

Periathritis of shoulder

L115©, LI 11©, LI4©

Backache

BL23©, DU3©, BL54©, BL40®, BL26©,DU4@

Prolapse of lumbar intervertebra disease

BL23®, GB30©, DU4®, BL40®, DU3©

Insomnia

11T7©, SP6®, ST36©(Neurasthenia)

PC6®, GB20©, BL15®(Insomnia)

Headache

EX-HN5®, GB14®, LI4©, SJ5®, ST36©

Hemiprosophegia

EX-HN4©, BL2©, ST6®, ST7®, GB14®, ST4©

Toothache

ST7®, ST6®, EX-HN5®, GB20©

Neuralgia

SJ6©. LR5®, РСбф, GB34©

Brachial Plexus Neuritis

1)114®, LI15®, Llll©, LI 10©, LU50, РСбф

Ischimia

GB30©, BL23®, BL40®, GB29®, GB34@, BL57®, BL37©, BL36©, ST36©


(Last Pege)

Cases

Acupoints

Tenosyonovitis

L15®, LU7®, LI4©

Sequela of hypertension or epplectic

РСбф, Llll©, LI 10©, ST36©

(PS: Every group of acupoints should not be cure more than 5 minutes)

Cerebral arteriosclerosis

GB20@( two sides)

Hemiplegia

UPPER LIMBS: GB21®,LI11©, LI4®, SJ5© LOWER LIMBS: BL40®,BL60®,GB39®,GB34©

Climacteric

DU2®, DU 14®, RN4©, BL23®, SP6©

Syndrome

SP6©,GB34©,BL28®, RN3©, BL23®, RN6©

Lobules of mammary glard.

ST18O, ST17©, BL18®, RN17©

Poliomyelitis

UPPER LIMBS: L115©, Llll©, РСбф, LI4© LOWER LIMBS:GB30®, BL37©,GB34©,ST36©

Nasosinusitis

GB14®, LI2O0, BL2®, EX-HN5©

Stomachache

RN120, BL21®, ST25©

Menalgia

RN6©,RN4©,RN3©,ST29®,ST28©,LR3®,SP6©)

Sexual Prospermia

ST38®, RN2©, RN4©, BL23®, DU4@, DU2©

Constipation

BL25©, SJ6©, Llll©, ST36©

Tinnitus

S.I19, SJ17®

Abdominalgia

RN120, ST36©, S1’44©

Obesity

ST34®, ST40®, ST36©

Cervical spondylitic syndrome

GB20@, BL10@, DU14®, LU7©


NOTES: Please check the enclosed acupoints map then find out the acupoints position.


(Next Pege)


Therapy Instrument Model:KA-F25


Therapy Instrument Model:KA-F25





Pbqsio-Stiin


The diagram of common Acupoints


The diagram of common Acupoints


Phqsio-Stiffl


©DU20


0ST17


0GB24


О STI8

0 LU5

0 RN12

©ST8

®ST25

©PC6
® LU7
ФРС7


©HT7


©ST28

©ST29


©EX-LE4


©ST37

0ST36


0ST44


ST8®


RN22 ф


0 LI20

0RN24


О DU23 0EX-HN3


GB14®

EX-HN4 ф

BL2©

ST4©


ST31


LI15®


RN17©


RN14©

RN13©

РСЗФ _

-RN8®

RN6©

RN40

EX-UE9 ф

LU1O0


®DL'14

®DU12

®SI9

©DU8 ©DU7

®DU4

©DU3 ©BL28


RN3©

RN20



ST34 G


ST40®


ST38 ®


ST41 ф


©SJ15 ©DU2 ©DUl





GB20 ф
EX®


GB21®

BL13®
SIH®


BL17®
BL18®


BL 19®
B1.20®
BL230
BL2S®
BL26®
BL54®


SJ6®

LIS®
SJ4®


BL35®

BL36®

BL37®

BL40®


BL57®


BL59®


Therapy Instrument Model:KA-F25


Therapy Instrument Model:KA-F25


8«<



Phqsio-Stioi


The diagram of common Acupoints


©S119

®SJ17


©S19


©SJ10

©Llll

©I.110

©SJ5

©GB29

©GB30

©L14

©LI3


©GB32

©GB33

© GB34


©GB39

© BL60





EX-HN5®

ST7®

ST6©

ST9©


SP10©

SP9®

SP«®

LR5©

SP6®

SP5®

LR3®

KU®


Therapy Instrument Model:KA-F25



Main Unit and Functional Fittings Sketch-map


Phqsio-Stim


Main Unit and Functional Fittings Sketch-map:


Time setting display


Window display
board





Outputl socket

Outputs socket

Outputs socket

4H Output4 socket




Circulation,
select/start-up


Power
indication
light

Power on-off


button

Function
indicalion


light group


Function
selection
composite key


Adjutment button of
treatment output sense:
outputl,outputs,outputs,output4


(Diagram 2)


Therapy Instrument Model:KA-F25


W«<



Phqsio-Stin)


Main Unit and Functional Fittings Sketch-map


Connect Main Unit With Functional Fittings Sketch-map :


TYPE STOCK:EGYPF24AD0703-16SHOW COMPUTER CODING:624010311070316





Output 2-


Outputs—





Each Partj|






Electrode pad





Cable


>»11


Therapy Instrument Model :KA-F25



Usage and Operating Instructions


Phqsio-Stiffl


Operating Procedures About the Operation Order of Treatment Methods^

  1. Connect the plug of the main unit power supply to the plug of net power supply.

  2. Connect the electrode, electrode cable , etc according to the Main Unit and Functional Fittings Connection Sketch-map and press the mains switch to the status of ON, ready for operation (stand by).

  3. fix the elastic belt on the body for therapy.

  4. Time setting: press “Time” can set up the fixed treatment time within 0-30 mins.

  5. Press the "Pulse Choice" button, there are six kinds of treatment modes to be selected, the certain kind of treatment mode will flash when chosen.

  6. There are low frequency (1-1000Hz) and medium frequency (1000-5000Hz) treatment.

The default is MF mode. Press the "М-Wave L-Wave" button to switch. The indicator shows orange for medium frequency; it shows green for low frequency

  1. Startup: After setting up the treatment methods, time setting, press “ Keep / Cycle” . The apparatus is then on and begin to work (output pulse wave is transferred to the electrode) the apparatus work under the “Keep” mode.

  2. Repeat and function selection setting: sharing one key certain treatment pulse wave in

the “Current Mode” can be selected, otherwise it works as the repeat function; “Treatment” should be cooperatedly used. The twinkling blue light symblizes the cycle operation while the long lighting means operating under selection.

  1. Output 1-2 and Output 3-4 adjusting: respectively press “+” and in Output group 1 -2and Output group 3-4 16 grades in force sensor degree and grade 16 is the

maximum output force degree. The red indication light beside the main switch is under the condition of twinkling which functions as warning: namely the tendency that the output would be too strong should be noticed.

  1. .During the treatment, user had better try best to relax. And when the treating part “adapt” to it, the intension can be turned up advisably (just a little).

  2. Therapeutic time (or under the construction of doctor): on the same part: 1 -2 times per day, 10-20 min per time and the period of treatment covers 7 days; to the severe patient: 2-3 times per day, 15-30 min per time and advisably increase the periods of treatment.

  3. When finishing the treatment, the apparatus will give off the sound hint of “B*” , and automatically cut off every output channel at the same time.The relevant indication lights will go off, leaving the indication lights of standby state and power supply.

  4. After use, the switch should be turned to OFF and the power supply should be pulled out and properly stored for the next use.


Therapy Instrument Model:KA-F25


»2«<



Phqsio-Sti№


Usage and Operating Instructions





Operating Procedures—About the Simple Graphic Operation Order





Press the main switch: indication light of power supply is A lit, which symbolizes tht the apparatus is on and under the standby state.





Press mode next: it goes next treatment type when pressing once


q Press setting key "Time": the setting therapeutic time can be within 0-30 min.


Press mode last: it goes last treatment type when pressing once


Press the switch key: specific content please see Operating E Procedures About the Operation Order of Treatment

Methods.


Connect the electride pad with cable Then adjust the p strength output till feeling comfortable. In this way, you can carry out the treatment and massage.


13


Therapy Instrument Model:KA-F25





Notes and Safety Precautions


Phqsio-Stiai


■ Safety Precautions Warning Symbols and Graphic Instruction

Warning

/ Symbols

Connotation

A Danger

Misapplication will cause the dangers of severe sickness or accident.

A Warning

Misapplication will cause the possibility of sickness or accident.

A Notes

Misapplication will cause the possibility of sickness, accident or article damage,/


Graphic Symbols

(^)

Q means prohibition (unallowable things)

Specific prohibition is Q shown with words or pictures in



(T)

® means compulsion (things must obey)

Specific compulsion is ® shown with words or pictures in



И Ш

means type II interior power supply type BF model




NOTICE necessary precautions, general precautions




Intention for the Instruction to quote this symbol: uncertain factors or / the meaning of "otherwise" , /


■ Safety Precautions Precautions for Users


/j\ Danger

Never use with the following medical electronic apparatus together:



  1. Interior built-in medical electronic apparatus such as heart pacemaker, etc.

  2. Medical electronic apparatus for life maintaining such as artificial heart and lung, etc

  3. Medical electronic apparatus such as electrocardiograph that will cause the malfunction of these medical electrical apparatus.

  4. When connecting the high frequency operation apparatus and therapeutic apparatus to the patient's body, the part attached to the therapeutic electrode might be burned and the device would be damaged.

  5. When using the therapeutic apparatus (1 .OM) near the shortwave or microwave device, its output might be unstable.

  6. Medical electronic apparatus such as Gamma knife will cause the wrong linear incision of these medical apparatus.


14


Therapy Instrument Model:KA-F25



PhqsioStim


Notes and Safety Precautions










Warning


Following patients avoid use or use after consulting the doctor:

1 s Acute disease patients and the reason is not found.

2> Abnormal change of blood pressure patients and the reason is not found.

3s Skin sensory disturbance or skin ulcer part

4> Abnormal heart failure or heart disease patients.


  1. 5, Hyperthyroidism and positive patients.

■i-' 6, Women in period of menstruation or pregnancy.

7s Children and people incapable to express the consciousness.

8 s High feverer.

9 s Malignancy patients




1 s During the period or application, if the patch electrodes are to be moved to other parts or to another person, the power must be switched off and reset, otherwise powerful electrical puncture and shock would be suffered.

2s During the period of application, if sickness is felt because of the abnormity of the apparatus, please stop using it. And please consult the doctor or distributor if abnormity of the body or skin is felt.



3s Do not use it in the bathroom and during the shower, otherwise powerful electrical puncture and shock would be suffered.

  1. Do not use it when sleeping, and the guardian should be present if necessary, otherwise this apparatus cannot be effectively controlled.

  2. Do not use this apparatus while driving the vehicles (and other means of transportation, machinery device, etc), otherwise traffic or other safety accidents might happen.

  3. Do not apply the patch electrodes on to the body for a long time and the patch electrodes should be taken off immediately after the treatment, otherwise skin sickness will be caused.

  1. Do not randomly assemble, repair or alter this apparatus, otherwise breakdown or accident would occur.

  2. The tested qualified therapeutic apparatus outputs alternating pulse voltage. If the therapeutic apparatus breaks down, it will be possible that direct current outputs by certain amount, when the skin will feel abnormal, burning or no pulse jumping. Otherwise, the skin of the part attached to the electrode will emerge reddish swelling. If so, user should stop the apparatus and consult the doctor or distributor.


»> 15


Therapy Instrument Model:KA-F25



Notes and Safety Precautions


Phi|sio-Stiffl





Notes






When the output voltage or current (referred to the efficient value)
is adjusted to 50% of the maximum value (max value, counted by the
dial), it might exceed 10V or the current density of the electrodes
exceeds 2mA/cm2, so the user should pay special attention to:

1, the endurance for the output force degree and gradual proceeding


2, that the sequela of apoplexy or hemplegia patients is advised to
control the output force degree within 10~35% in their very first

use.


3, that the treatment for acupoints in the head and face is advised
to control the output force degree within 10-30%.

■ Attention—General Attention

  1. Clean the affected part with wet towel before therapy and apply the electrode ( patch electrode) after drying up.

  2. Electrode hshould adequately contact (press) the skin to improve the therapeutic effect. Change new patch if the long-term use makes the electrode stickness ageing and the patch is easy to slip.

  3. Moisten the skin with wet towel when the weather or skin is dry to improve the electrical conductivity thus obtaining excellent effect.

  4. The phenomenon that the stimulation of one electrode is strong while the other is weak will appear because of the pathological-change-induced insensiveness or varied sensibilities in different parts. In such a circumstance can the electrode with weak feeling be changed to another acupoint or two electrodes exchanged.

  5. Stop using the Device and consult the doctor if you feel sick during the therapy.

  6. It is normal to feel more painful for the therapy will promote blood circulation.

  7. Do not directly bring the two electrodes into contact with each other, which will result in damaging the Device.

  8. The Device is equipped with two modes of therapy which can be alternated according to the patient.

  9. Please drink a glass of water after the therapy to compensate for the lost water and take other activities after a short rest.


16


Therapy Instrument Model:KA-F25



Phqsio-Stim


Maintenance and Storage • Cleaning and Sterilization


Attention—preventive examination


  1. Examine whether the power cord is damaged or broken; whether the power socket is loose or bound to fall off.

  2. Examine whether the power switch, time control key, infrared thermotherapy key, therapy control key are flexible and the output strength adjusting knob is in order and smooth.

  3. Examine whether related fittings are sufficient and sound.


Maintenance and Storage • Cleaning and Sterilization


■ For the Main Unit


1. If the main unit is dirty, clean it with a piece of clean soft cloth. The extreme dirt can be wiped off with the soft cloth dipped with (diluted) neutral detergent and afterwards clean it with another piece of clean soft cloth dipped with clean water.

2. Sterilize it by wiping with medical alcohol 75% if necessary and the method as aforesaid. St Do not clean it with volatile chemical preparations or immit water or liquid into the main unit.




■ For the Electrode


  1. Keep the electrodes clean and keep them off dust, oily objects and others, otherwise the stickness will weaken and the life expectancy will ultimately shorten.

  2. Once the pad is weakened or the skin feels stinging for the patch electrode

is dirty, clean the electrode with clean water meanwhile softly wiping it with a finger for several times and reapply it after it is completely dry.

  1. Sterilize it by means of wiping it with medical alcohol 75% if necessary. The convenient method is to evenly clean the surface with a cotton swab dipped with alcohol 75%.

St Do not wipe the surface with tissue, cloth, etc; do not scratch the surface with nail or brush; do not put it in the sun.


■ Storage of the Whole Machine


1. The whole machine (including fittings) should be put in the well-ventilated, dry and clean indoor environment.

2. Please put it beyond childrens reach.




Therapy Instrument Model:KA-F25





PhqsioStim


Graphic Instructions - Fittings Index








Wash electrode


Leg treatment


Troubleshooting:

Faults

Reasons

Solutions

No output (Indication light off)

1. Is the power well connected?

Reconnect the power or change a power socket.

No output or unstable output (Indication light on)

1. Is the plug of electrode firmly inserted in the socket?

Reinsert the plug.

2. Is the connection between the electrode cable and each fitting normal?

Sort out the connection.

3. Is the electrode cable broken?

Change the electrode cable.

4. What is the property of the liquid medicine?

Apply liquid medicine, such as medical liquor (oily liquor is nonconductive).

Skin reddens or stings

1. Is the connection between electrode patch and skin good?

Clean the skin and stick it.

2. Does the therapy time last too long?

Under 30 minutes on the same part for each time.

3. Is the electrode patch not cleaned or changed for a long time?

Solve it under the relevant solutions in instruction.


Therapy Instrument Model:KA-F25


18 «



Phqsio-Stim


Other Significant Information


[Declaration]

  1. The contents in this instruction are in conformity to the examination and approval document of “Instruction”

  2. Please directly contact the manufacturer if found any doubt on this product

  3. Similar pictures or words with those of this Company are piratic.


Fittings Index


  1. Main unit 1 unit

  2. belt 4 pcs

  3. electrode cable 4 pcs

  4. electrode pad 8 pcs

  5. Usage Instruction Index 1 pcs