Voltage calculation in the regulation of tap

Tarmoq kuchlanishi, kV

1 (Umax.VN)

+16,02

133,4

2

+14,24

131,4

3

+12,46

129,3

4

+10,68

127,3

5

+8,9

125,2

6

+7,12

123,2

7

+5,34

121,1

8

+3,56

119,1

9

+1,78

117,0

10 ( US.VN )

0

115,0

11

-1,78

113,0

12

-3,56

110,9

13

-5,34

108,9

14

-7,12

106,8

15

-8,9

104,8

16

-10,68

102,7

17

-12,46

100,7

18

-14,24

98,6

19 ( Umin.VN )

-16,02

96,6

Ko'proq ko'rsatish
Dlya udobstva polzovaniya , mumkin qo'llash tablitsy 1 – 4 GOST 12965-85, gde qabul qilish znacheniya nominal napryajeniy otvetvleniy obmotok , uchun transformov s privodami pereklyuchayushchix qurilma (PBB) va uchun transformov s tartibga solish napryajeniya pod nagruzkoy (RPN) 110 kV va 150 kV .
nominalnye napryajeniya otvetvleniy obmotok




Vsyu literaturu , kotoryyu ya ispolzoval pri napisanii dannoy stati , Vy mumkin skachat , kliknuv po "SKAChAT" tugmasini bosing .
SKACHAT
Adabiyot :
1. Raschet tokov korotkogo zamykaniya uchun releynoy zashchity . I.L.Nebrat . 1998 yil
2. GOST 721-77 – Sistema elektrosnabjeniya , seti , istochniki , preobrazovateli va priemniki elektr energiyasi energiya nominalnye napryajeniya svyshe 1000 V.
3. GOST 12965-85 – Transformator silovye maslyanye obshchego naznacheniya klassov napryajeniya 110 va 150 kV .
Vsego nailuchshego ! Do novyh vstrech na sayt Raschet.info.
Download 146.52 Kb.

Do'stlaringiz bilan baham:
1   2




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling