Loyihalanayotgan teplovoz yuk tortuvchi reduktori parametrlarining hisob-kitobi


Download 299.09 Kb.
bet2/5
Sana31.03.2023
Hajmi299.09 Kb.
#1314188
1   2   3   4   5
Bog'liq
Kurs ishi 2-qism TVL-14

FD∞nam=3,6 PD∞nam / Vh =3,6*411/50=29,5 (6)
MD = 9,5PD / nD; MD∞amal=9,5 PD∞amal / nD= 9,5*434/702,8
MD∞nam=9,5 PD∞nam / nD= 9,5*411/702,8 (7)
nD =ndmaxVh /Vkon=2249*50/160 (8)
Bunda, PD bitta yuk tortuvchi elektrodvigatelning quvvati, kVt;
Vh – teplovozning mo‘ljallangan harakat tezligi, km/s;
nD yuk tortuvchi elektrodvigatel yakori aylanishining uzoq muddatli chastotasi, min-1
ndmaxyuk tortuvchi elektrodvigatel yakorining maksimal yo‘l qo‘yilishi mumkin bo‘lgan aylanish chastotasi. Bunda 2200/2300 min-1ga teng bo‘lgan hisob-kitob e’tiborga olinadi.
(6, 7, 8) tenglamalarni formulaga (5) qo‘ygan holda quyidagi ko‘rsatkichni olamiz:
μu.n. =0,19ndmax Dg’/Vkon


μu.n. =0,19*2249*1,22 / 160=3,25

Yuqorida keltirilgan formula yordamida aniqlangan µu.n. uzatuvchi son, teplovozning uzoq muddatli harakatiga mos keladigan, uzoq muddatli ish rejimida FD, MD ko‘rsatkichlarini aniqlab berishdan tashqari, yuk tortuvchi elektrodvigatelning mustahkamlik shartini, yakorning konstruksion tezlikda yo‘l qo‘yilish mumkin bo‘lgan ko‘rsatkichdan ndmax oshmaydigan aylanish chastotasini ta’minlaydi.


G‘ildiraklar juftligi va yuk tortuvchi elektrodvigatel yakorining o‘qi oralaridagi farqni ko‘rsatuvchi uzatuvchi sonning yakuniy qiymati, qabul qilingan A sentral uzunligini hisobga olgan holda qo‘yiladi.