B u h o r o n e f t n i q a y t a I s h l a s h z a v o d i
B u h o r o n e f t n i q a y t a I s h l a s h z a v o d i
«BNQIZ» MChJ
«ERESCO 42 MF3» rentgen
qurilmasini ishlatish bo`yicha
yo’riqnoma
IEO 007-045:2022
Taftish: 2
5-bet 10-betdan
II. ERESCO 42 MF3
Nominal kuchlanish 200kV
Quvurdagi tok kuchi 0,5-10mA (4,5mA/200kV)
Chiqish quvvati 900Vt
Fokus nuqtasi 1,5 (IEC 336)
Anod materiali volfram (w)
Anod haroratining maksimal darajasi 100° C
Anodning egilish burchagi 20° (mexanik)
Rentgen nurining chiqish shakli elliptik 40°×60°
Ichki filtrlash 1mm. Be.
Ish sikli (harorat = 20°C) 100% (rejimning davomiyligi 60 minutgacha)
Og'irligi 23 kg
Quvurning diametri 160mm/175mm (rezina halqa bilan)
Oqim va kuchlanishning barqarorligi ± 1%
Quvvat iste'moli 1,6 kVt.
Ekspozitsion nurlarining ta'sir qilish dozasi rentgen blokining ort tomonidan (500 ± 20) mm masofada,
to'g'ridan-to'g'ri nurlanishda 100 soniya davomida kuchlanish iste’moli (200 ± 2) V mkKl / kg (mR) ),
kamida -154,8 (600) bo’lishi kerak.
4.
Qurilmani ishlatish qoidalari.
Qurilma ikkita asosiy qismdan iborat bo'lib, rentgen trubkasi joylashgan emitent va birlamchi
kuchlanish manbai, boshqaruv va nazorat qilish vaqtlarini o'zgartira oladigan
boshqaruv panelidan
tashkil topgan. Qurilma tarmoq boshqaruv paneli yordamida 220V o'zgaruvchan tok tarmog'idan