- 6.6.4 Antistatic or Conductive Clothing. 6.6.4.1
- 6.6.5 Gloves.
6.6.3* Personnel Grounding Devices.
6.6.3.1 Where ESD footwear will not provide adequate per- sonnel grounding, supplementary devices should be used. Such devices include wrist straps, heel/toe grounders, and conductive overshoes. They should be selected so that accu- mulation of hazardous static electric charge is prevented, while the risk of electrocution is not increased. In most practi- cal situations, grounding of personnel is achieved by ensuring that the resistance from the skin to ground is approximately 10 8 ohms or less. The need to protect against electrocution via a grounding device imposes a minimum resistance from skin to ground of 10 6 ohms. Based on skin contact and contact with the floor, especially during activities where the entire sole of the footwear is not in contact with the floor (e.g., kneeling), effectiveness can be compromised. Grounding devices should have a minimum resistance of 10 6 ohms for shock protection. 6.6.3.2 The simplest type of commercial device is a grounding bracelet with a built-in resistor, typically giving a resistance to ground of about 10 6 ohms for shock protection. Wrist straps of this type have the greatest utility at ventilation hoods and at other locations where limitation on the operator’s mobility can be tolerated. Breakaway wrist tether systems could be nec- essary where emergency egress is needed. A hood can be equipped with two external coiled grounding cords with removable cuff attachments, the latter being kept by individ- ual users. 6.6.3.3 Ground continuity should be checked periodically to the manufacturer’s specified limits using a voltmeter or volt ohmmeter or a commercial tester. 6.6.4 Antistatic or Conductive Clothing. 6.6.4.1 Although silk and most synthetic fibers are excellent insulators, and undergarments made from them exhibit static phenomena, no conclusive evidence exists to indicate that wearing such undergarments constitutes a hazard. However, removal of outer garments is particularly hazardous in work areas, such as in hospital operating rooms, explosives manu- facturing facilities, and similar occupancies and where cloth- ing is contaminated by flammable liquids. Outer garments used in these areas should be suitable for the work area and should be antistatic. NFPA 99, Standard for Health Care Facilities, provides information on test methods for evaluating the anti- static performance of wearing apparel. 6.6.4.2* Although usually a very small likelihood of ignition by a grounded person due to any type of clothing exists, the charging of personnel (which can occur, for example, when personnel are getting out of a forklift truck) is greatly increased by clothing having high resistivity. 6.6.4.3* In oxygen-enriched atmospheres, such as could be present in liquid oxygen filling plants, vapor from the cooled gas can permeate the employee’s clothing, rendering it more combustible. A static electric charge that accumulates on the person and then suddenly discharges can ignite the clothing. 6.6.5 Gloves. Gloves should be antistatic or conductive with the same resistivity as prescribed for footwear. Gloves should be tested in conjunction with the footwear. Download 1.59 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling