7 Conclusions
The energy audit and the investigation of energy efficiency opportunities at Bodycote
Värmebehandling AB in Angered can be summarised with the following conclusions:
• The plant consumed 9 590 MWh/year of electricity and 120 MWh/year of district
heating at the start of the project.
• 68% of the energy was consumed in the process and 32% of the energy was consumed
in the support processes.
• The largest part of the energy consumption in the process is consumed in the main
furnaces.
• The electricity consumption could be decreased with 753 MWh/year by energy
housekeeping measures.
• The electricity consumption could be further decreased with 418 MWh/year and the
district heating demand could be removed by energy saving investment measures.
• The proposed energy housekeeping measures and energy saving investment measures
could together reduce the energy cost with approximately 1.2 MSEK7year and reduce
the carbon dioxide emissions with approximately 740 tonCO
2
/year.
• If all proposed measures were implemented, the combined investments would have a
payback time of three years and a net present value of almost 19 MSEK over a time
frame of ten years and with current energy prices.
47
Do'stlaringiz bilan baham: |