254
POWER PLANT ENGINEERING
Table 8.1. Technical Data about Diesel Engine-Steam Turbine Cogeneration Power Plant
No. of diesel
engine generator units
2 × 24.4 mW
Rating of each unit at speed
24.8 mW at 100 rpm
No.
of cylinders per engine
9
Bore/stroke
800
2300
mm
Diesel engine mitsui/MAN B and W
2 Stroke Low Speed
Generators 2 Nos. 11 kV, 50 Hz, 100 RPM
29.8 kVA each
Steam Turbine
0.67 mW
Gas Turbo Generator System
0.5 mW
Location
Macau, Canton, China
Heat Radiation Loss
248 kW (0.5%)
Charge Air Cooler
6547 kW (13.2%)
Fresh
Water Cooler
3472 kW (7.0%)
Lube Oil Cooler
2034 kW (4.1%)
Fuel Oil 49598
kW (100%)
Diesel Engine 9K80 MC-S
Exhaust
Gas
Turbo Compound System
(TCS)
Fuel Oil Preheating
595 kW (1.2%)
Exhaust
Gas to
Stack
11160 kW (22.5%)
Generator Loss
744 kW (1.5%)
Generator
Turbogenerator
Boiler
TCS
471 kW
Turbogenerator
670 kW 50%
24.8 MW
Measured at site
Output
23.64 MW
Fig. 8.17. Heat Balance of a Diesel Engine Power Plant.