- ( c ) Low Lube Oil Pressure.
- ( d ) High Lube Oil Temperature.
- ( e ) Excessive Vibration.
- (2) Modulating Controls
(b) Turbine Overspeed. The turbine overspeed control is similar to the prime speed control as
shown in Fig. 9.22. In this case, the reference speed is the maximum allowable speed instead of rated speed. The speed sensor could be a centrifugal governor, a tachometer generator or magnetic pick up. If the speed increases a certain fixed value, the speed acts upon the relay system to shut down the fuel valve. (c) Low Lube Oil Pressure. It is essential to protect the turbine from low lube oil pressure to ensure proper lubrication and cooling of the turbine bearings. This is accomplished by the use of a pressure switch in the lube oil supply line. The switch operates an alarm signal or shut down fuel valve if the oil pressure drops a safe valve. GAS TURBINE POWER PLANT 289 (d) High Lube Oil Temperature. High lube oil temperature in the lubrication system is a dan- gerous signal as it is an indication of low lube oil supply or failure in bearings, gears, etc. This protection is generally accomplished through the use of a temperature-sensing device immersed in the lube oil. The sensing device may be a thermal switch, which triggers an alarm or shut down the turbine. (e) Excessive Vibration. A slight increase in vibration is a cause of warning. Protection against vibration is accomplished by stalling one or moves vibration pick-ups. The output signal is fed to a monitoring device, which may shut down the turbine if the vibration increases a certain value. (2) Modulating Controls The purpose of modulating control is to sense an impending malfunction or a condition, which could adversely affect turbine life and make some modification to the operating condition of the turbine in order to alleviate the undesired conditions. An example of this control may be maximum turbine inlet temperature and maximum speed. The modulating control is more complex and more costly than the shutdown control. But it offers and advantage in allowing a turbine or turbine driven plant to continue operating when normally a shut down occurs. There are some conditions such as high vibrations and low lube oil pressure which cannot be taken care by corrective measures as in this case shut down of the turbine is essential. Modulating controls for maximum turbine inlet temperature and maximum speed are slight modi- fications for over temperature and overspend controls. Download 3.45 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling