Quality control methods for
Download 1.63 Mb. Pdf ko'rish
|
sifat nazorati (englischa)
- Bu sahifa navigatsiya:
- Units of measurement
- 2. Powder fineness and sieve size Powders
Size of cut
Medicinal plant materials are used either whole, or in cut or powdered form. Cut medicinal plant materials are prepared by cutting or crushing the plant into small pieces. The cut is graded according to the aperture size of the mesh of the sieve through which the material will pass, and is indicated as follows: Aperture size (mm) coarse cut 4.00 medium cut 2.80 fine cut 2.00 Powders are discussed in section 2. Quality control methods for medicinal plant materials Units of measurement The names and symbols for units of measurement used in this manual conform with those used in The international pharmacopoeia (5) and those of the International System of units (SI), developed by the General Conference of Weights and Measures (CGPM) in collaboration with other international organizations (6,7). Quality control methods for medicinal plant materials 2. Powder fineness and sieve size Powders The coarseness or fineness of a powder is classed according to the nominal aperture size expressed in hum of the mesh of the sieve through which the powder will pass, and is indicated as follows: Descriptive term Particle size Coarse (2000/355) All the particles will pass through a No. 2000 sieve, and not more than 40% through a No. 355 sieve Moderately coarse (710/250) All the particles will pass through a No. 710 sieve, and not more than 40% through a No. 250 sieve Moderately fine (355/180) All the particles will pass through a No. 355 sieve, and not more than 40% through a No. 180 sieve Fine (180) All the particles will pass through a No. 180 sieve Very fine (125) All the particles will pass through a No. 125 sieve Sieves The wire sieves used to sift powdered medicinal plant materials are classified by numbers that indicate their nominal aperture size expressed in µm. The sieves are made of wire of uniform circular cross-section, and have the following specifications: Number of sieve Nominal size of aperture Nominal diameter of wire Approximate screening area (µm) (mm) (mm) (%) 2000 2.00 0.90 48 710 0.710 0.450 37 500 0.500 0.315 38 355 0.355 0.224 38 250 0.250 0.160 37 212 0.212 0.140 36 180 0.180 0.125 35 150 0.150 0.100 36 125 0.125 0.090 34 90 0.090 0.063 35 75 0.075 0.050 36 45 0.045 0.032 34 The sieves recommended here have been selected from among those conforming to ISO standard 565, 1990. |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling