- ARGET I NTERVENTION T ARGET I NTERVENTION
- 2. Other inorganic substances
T ARGET I NTERVENTION 1. Metals Antimony 3 15 - 20 Arsenic 29 55 10 60 Barium 200 625 50 625 Cadmium 0.8 12 0.4 6 Chromium 100 380 1 30 Chromium III - 180 - - Chromium VI - 78 - - Cobalt 9 240 20 100 Copper 36 190 15 75 Dzhankeldy 500MW Wind Farm ESIA Volume 2- Main Text, Tables & Figures 137 C ONTAMINANT S OIL /S EDIMENT ( MG / KG DRY WEIGHT ) G ROUNDWATER ( µG / L ) T ARGET I NTERVENTION T ARGET I NTERVENTION Mercury 0.3 10 0.05 0.3 Mercury (inorganic) - 36 - - Mercury (Organic) - 4 - - Lead 85 530 15 75 Molybdenum 3 200 5 300 Nickel 35 210 15 75 Zinc 140 720 65 800 2. Other inorganic substances Chloride (mg Cl/l) - - 100 - Cyanide (free) 1 20 5 1500 Cyanide (complex) 5 50 10 1500 Thiocyanate 1 20 - 1500 Note: The soil values are calculated for a ‘Standard Soil’ with 10% organic matter and 25% clay. A case of environmental contamination is defined as ‘serious’ if >25 m³ soil or >100 m³ groundwater is contaminated above the intervention value. Source: Soil Remediation Circular 2009, Annex 1: Groundwater target values and soil and groundwater intervention values. (*Target values for soil refer to 2000 version as they are not present in the 2009) Where contaminants are found to exceed ‘intervention’ levels, this is considered to be a case of soil contamination, which is dangerous to the health of humans and the natural environment. Such a level of contamination should prompt a need for remediation, appropriate treatment and disposal. 5.5 Electric Magnetic Field 5.5.1 National Requirements Resolution of Cabinet of Ministers of Republic of Uzbekistan No.95 “On approval of general technical regulations of environmental safety” (2020). Requires the implementation of environmental safety measures for the protection of flora and fauna. This includes the prevention of death of wildlife species due to magnetic fields of power transmission lines and sanitary protection zones. Requires transformer substations in power transmission lines, their grids to have equipment (barriers, fences etc.,) to prevent animals from entering the territory of the substation. Decree of the Cabinet of Ministers of the Republic of Uzbekistan No.1050 “On approval of Rules for Protection of Power Grid Facilities, 2018”. Dzhankeldy 500MW Wind Farm ESIA Volume 2- Main Text, Tables & Figures 138 This determines the procedure for establishing protected zones for power grid facilities, as well as special conditions for using land located within the protected zones and ensure the functioning and operation of the said facilities. Construction of power grid facilities with 110, 220 or 500kV in protected areas of state nature reserves, protected areas of nature parks and state biosphere reserves etc shall be allowed with the permission of the Cabinet of Ministers of the Republic of Uzbekistan. Protected zones of power grid facilities shall be established on both sides of the power transmission line from the outermost wires and along the perimeter of substations at the following distances for voltages; o 110kV: 20 meters; o 220kV: 25 meters; and o 500kV: 30 meters. San Rules & Norms No. 0236- 07 “Sanitary norms and rules to ensure safety for people living near high voltage power transmission lines, 2007”. This regulation sets the requirements for ensuring public safety when overhead power lines pass over populated, unpopulated or inaccessible territories. It requires sanitary norms and rules to be followed in the design, construction and operation of overhead power lines. The distances corresponding to the projection onto the ground of the outer phase wires in a direction perpendicular to the overhead line as follows: o Up to 110kV/m: 10 meters; o Up to 220kV/m: 15 meters; o Up to 330kV/m: 20 meters; o Up to 500kV/m: 30 meters; and o Up to 570kV/m: 40 meters. In addition, SanPin 0236-07 specifies that EMF in population living areas is not to exceed 1.0kV/m and magnetic fields 80 A/m (equivalent to 100 138 μ T). 5.5.2 Lenders Requirements EBRD EU Council Recommendation 1999/519/EC on the limitation of exposure of the general public to EMF (0 Hz to 300 GHz) references and recommends ICNIRP derived limits as applicable “when the time of exposure is significant” that is the limits should apply to “areas where members of the public spend significant time in relation to the effects covered by this recommendation”. Download 6.64 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling