Dzhankeldy Wind Power Project
Overhead Transmission Lines & Substation
Download 6.64 Mb. Pdf ko'rish
|
56086-001-esia-en
3.1.8.5
Overhead Transmission Lines & Substation Resolution of Cabinet of Ministers of Republic of Uzbekistan No.95 “On approval of general technical regulations of environmental safety” (2020). Requires the implementation of environmental safety measures for the protection of flora and fauna. This includes the prevention of death of wildlife Dzhankeldy 500MW Wind Farm ESIA Volume 2- Main Text, Tables & Figures 104 species due to magnetic fields of power transmission lines and sanitary protection zones. Requires transformer substations in power transmission lines, their grids to have equipment (barriers, fences etc.,) to prevent animals from entering the territory of the substation. Decree of the Cabinet of Ministers of the Republic of Uzbekistan No.1050 “On approva l of Rules for Protection of Power Grid Facilities, 2018”. This determines the procedure for establishing protected zones for power grid facilities, as well as special conditions for using land located within the protected zones and ensure the functioning and operation of the said facilities. Construction of power grid facilities with 110, 220 or 500kV in protected areas of state nature reserves, protected areas of nature parks and state biosphere reserves etc shall be allowed with the permission of the Cabinet of Ministers of the Republic of Uzbekistan. Protected zones of power grid facilities shall be established on both sides of the power transmission line from the outermost wires and along the perimeter of substations at the following distances for voltages; o 110kV: 20 meters; o 220kV: 25 meters; and o 500kV: 30 meters. San Rules & Norms No. 0236- 07 “Sanitary norms and rules to ensure safety for people living near high voltage power transmission lines, 2007”. This regulation sets the requirements for ensuring public safety when overhead power lines pass over populated, unpopulated or inaccessible territories. It requires sanitary norms and rules to be followed in the design, construction and operation of overhead power lines. The distances corresponding to the projection onto the ground of the outer phase wires in a direction perpendicular to the overhead line as follows: o Up to 110kV/m: 10 meters; o Up to 220kV/m: 15 meters; o Up to 330kV/m: 20 meters; o Up to 500kV/m: 30 meters; and o Up to 570kV/m: 40 meters. Download 6.64 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling