Kuchlanish isrofini xisoblaymiz


Download 0.64 Mb.
bet6/12
Sana31.01.2024
Hajmi0.64 Mb.
#1830718
1   2   3   4   5   6   7   8   9   ...   12
Bog'liq
Kurs ishi yechimi Zayridinov Dilshod

Kuchlanish isrofini xisoblaymiz.


[kV]
ΔU%=100% *ΔU / Uh =100%*5,5/110=4,9%;


Liniyadagi quvvat va energiya isroflarini xisoblaymiz;

STrKir= 20,127 +j 19,28 [MBA]
SL= STrkir - ΔQs= 20,127 +j 19,28 – 1,65 = 18,47 +j 19,28 [MBA]
Bu erda: ΔQs=B*Un2
ΔQs=136,5 *1102 = 1,65 [MVar]
Aktiv quvvat isrofi:

=1,31 [MVt],
Reaktiv quvvat isrofi:

=1,29 [MVar]
ΔSL = ΔPL +j ΔQL = 1,31+j1,29 [MVA] endi liniyadagi energiya isrofini xisoblaymiz.
ΔA=ΔPL*τ=1,31*4000= 5240 MVt.s/yil


1-5
S5= 6+j4,5=7,5 [MVA]
Iste’molchining ishchi tokini xisoblaymiz:

Ishchi tokiga mos keluvchi simning ko‘ndalang kesimi yuzasini jadvaldan tanlaymiz.
Tanlash jarayonida temir-betonli tayanch qabul qilamiz AS-35 Uning kuchlanishi Uh=35 [kV]. Ruxsat etilgan toki Ipyx=175 [A]; Iirux yoki 175 >123 [A] qanoatlantiradi. Tanlangan simning pasport ko‘rsatkichlari jadvaldan yozib olinadi.
S=35 mm2; r0=0,95 Om/km; x0=0,445 Om/km; l=22,3 km;
Simning 1 kmdagi narxi K=31,3 mln.sum.
Umumiy narxi ΣK=lK= =698,7 mln. sum.








Kuchlanish isrofini xisoblaymiz:



ΔU%=100% *ΔU / Uh =100%*0,9/35=2,5%;
Liniyadagi quvvat va energiya isroflarini xisoblaymiz;

STrKir=6,06 +j 4,95 [MBA]
SL= STrkir - ΔQs=6,06 +j 4,95 – 0,7=5,36+j4,95 [MBA]
Bu erda: ΔQs=B*Un2
ΔQs= 57,7*1102 =0,7 [MVar]
Aktiv quvvat isrofi

=1,03 [MVt],
Reaktiv quvvat isrofi

=1,01 [MVar]
ΔSL = ΔPL +j ΔQL = 1,03+j1,1 [MVA] Liniyadagi energiya isrofini xisoblaymiz.
ΔA=ΔPL*τ=1,03*4000=4120 MVt.s/yil
5-3