Focused on Window to Wall Ratio and Window Performances and shgc


Download 1.17 Mb.
bet3/6
Sana02.06.2020
Hajmi1.17 Mb.
#113272
1   2   3   4   5   6
Bog'liq
I Dong Hyon Paper




and
show the thermal permeation rate and envelope composition of each building. This refers to the energy-saving design standards of buildings recently revised and enforced in June 2017 by the Ministry of Land, Infrastructure and Transport. Based on the energy saving design standard, the permeation rate of the apartment complex was 0.27W / · K in the case of direct contact with the outside of the outer wall, and 0.37W / · K in the case of indirect facing. Right 0.26W / · K, bottom is 0.31W /K was applied.

3.3 Simulation conditions and cases
The analysis model setting conditions for the energy performance analysis of the building to be analyzed are shown in
. Due to the characteristics of the residential space, the building to be analyzed was continuously operated for 24 hours to set the usage time and operation time. The cooling-heating set temperature was set based on 20 ℃ for heating and 26 ℃ for cooling, and was selected by referring to the operation regulations of the building energy efficiency rating certification system announced by the Korea Energy Agency. The weather data for each region required for simulation was set with reference to weather data provided by the Korean Solar Energy Society.
shows the simulation schedule of the building to be analyzed. As shown in the figure, the schedule is divided into weekdays and weekends, occupants and lights, and equipment.

Heat Exchange Rate of Buildings for Analysis


part

Material name (outdoor-> indoor)



Thermal conductivity

(W / mK)


Thickness (mm)

Heat transmission rate

(W/m2·K)


Outer wall (direct

Outside air)


Resin mortar

0.7

5

0.270


Bead method insulation board

0.036

130

concrete

2.3

200

Cement mortar

1.4

10

Paper wallpaper

0.17

0.5

Outer wall (indirect

Outside air)


Resin mortar

0.7

5

0.370


Bead method insulation board

0.036

90

concrete

2.3

200

Cement mortar

1.4

10

Paper wallpaper

0.17

0.5



Bare concrete

2

80

0.260


Bead method insulation board

0.036

50

concrete

1.6

210

Bead method insulation board

0.036

80

Gypsum board

0.18

9.5

Roof (indirect

Cement mortar

1.4

40

0.310


Lightweight foam concrete

0.13

50

Bead method insulation board

0.036

85

concrete

1.6

210

Gypsum board

0.18

9.5



Structure of Building Subject to Analysis

outer wall

(Direct air)



outer wall

(Indirect air)







roof

(Indirect air)



floor

(Indirect air)










Energy Analysis Conditions Overview

division

contents

Heating set temperature

20℃

Cooling set temperature

26℃

Cooling and heating time

24hours continuous operation

Inje fever load

0.04/

Lighting load

4w/

Equipment load

14w/

Ventilation rate


AirCon space: 0.7ac/h

Non- AirC space : 2ac/h