Pursuant to Article 116 of the Energy Law
Download 0.65 Mb. Pdf ko'rish
|
Serbian Grid Code-1-43
- Bu sahifa navigatsiya:
- 4.2.2. C ONNECTION / INTERCONNECTION SCHEME 4.2.2.1.
INTER-
CONNECTION OF ALL TYPES OF FACILITIES 4.2.1. T ECHNICAL CRITERIA 4.2.1.1. The technical criteria from the section 3.2 of the Code must be met after connecting a facility of the transmission system user. 4.2.2. C ONNECTION / INTERCONNECTION SCHEME 4.2.2.1. JSC EMS act laying down connection and inter-connection, determines the scheme of connection and inter-connection. 4.2.2.2. A facility can be connected or interconnected in several directions. For each of these directions, adequate switchgear, protection, measurement and control equipment shall be provided for the part which belongs to the transmission grid and the part which belongs to the facility of the transmission system user. 28 4.2.2.3. The scheme for connection/inter-connection of the facility is determined on the basis of all available data and proposals, in order to set standard switchyard. In this respect the following is taken into account: - Single-pole scheme of the facility and connector (in case of connection); - Operating characteristics of the facility and technological process; - Standard operating procedures and for this type of facility; - Possibility for delivery of power to the facility of the transmission system user from the distribution or other grids; - Consumption of the facility during normal operation or during any foreseeable changes. 4.2.2.4. The scheme for connection/inter-connection must foresee: - Prospective development of the facility and transmission system; - Circuit breakers of appropriate technical characteristics that enable selective disconnection of transmission lines, transformers and busbar system in the facility of the transmission system user and neighbouring facilities; - Disconnectors (output and busbar for transmission lines, busbar for transformers and bus coupler bays); - Earthing elements (for the transmission line fields, 400 kV transformer fields, as well as for 400 kV busbars); - Measuring equipment; - Telecommunication equipment that can affect transmission capacity of elements of the grid 400 kV, 220 kV, 110 kV. 4.2.2.5. Each connection between the facility of the transmission system user and transmission grid must be operated through a breaker that is able to break the maximum short circuit currents at the connection/inter-connection point. 4.2.2.6. Coordination of insulation at all breakers, disconnectors, earthing elements, power transformers, voltage transformers, current transformers, surge arresters, insulators, equipment for grounding the neutral point, capacitors, silencers and coupling equipment, shall be in accordance with the IEC standards. Download 0.65 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling