4 – amaliy mashg‘ulot (2 soat)
Tok transformatorlarini tanlash.

a) tok transformatorlarini tanlash sharti bo‘yicha nominal toklarni aniqlaymiz


INTT INTR (2,1)
INOM t1(t2) = = = 52,5 A
Kuch transformatorini nominal toki asosida unga yaqin kattaroq bo‘lgan nominal tokli tok transformatorini tanlaymiz. [1]. Uning qiymati IN birlamchi. TT = 75 A bo‘ladi.
SHunda transformatsiya koeffitsienti = = = 15
Xuddi shunday:

INOM t3 = = = 66 A



= = 15

INOM t4 = = = 26 A



= = 6

b) Elektr uzatish liniyasi (EUL) uchun:
INTT IRUX (2,2)

IRUXl1(l2) = 210 A , tok transformatori INTT = 300 A tanlaymiz.
Unda: = = 60
Xuddi shuningdek:


IRUX l3 = 175 A

= = 40

IRUX l4 (l5) = 80A

= = 20

IRUX l6 = 65 A

= = 15

Elektr tarmog‘ini xar bir elementi uchun releli himoya qurilmalarini xisoblashda tok transformatorlarini alohida tanlash mumkin.
YAkka xoldagi SN = 4000 kVA quvvatli transformator uchun tokli kesim himoyani, gazli himoya va ortiqcha yuklanishdan himoyalash uchun maksimal tokli himoyani tanlaymiz.
a) birinchi pog‘ona. RT – 40 rele ishlatilgan selektiv bo‘lmagan kesim himoya qabul qilingan.
IXI = KZ* I (3)KT maks tashki. = 1,3* 1973*10/35 = 733 A
T – 3 transformator himoyasi uchun .
Transformator tok uchburchak sxemada ulangan. SHuning uchun
KSX = 3 KSX = 2
IRI = KSX* = * = 84,6 A
KSEZ = * = 2* = 1,43 < 2
Tokli kesim himoya sezgir bulmagani uchun differensial himoyani urnatamiz.
Bo‘ylama differensial tokli himoya.
Kuch transformatorning nominal toklarini topamiz:
INOMyuk = A
INOMpk = A
Kuch transformatorining chulgamlari - 11 guruxda ulangan.
Himoya zanjirida toklarni burchak siljishini kompensatsiya kilish uchun kuch transformatorlarini yukori kuchlanishli tomonidagi tok transformatorlar sxemasini uchburchakka, past kuchlanish tomonidagi tok transformatorlarini sxemasini esa yulduzcha ulaymiz.
SHunda,
Inom. tt yu.k > A
= = 30;
Past kuchlanishli tomon uchun
Inom. ttp > A
= = 60
YUkori va past kuchlanishli tomonlardan differensial himoya elkalariga keladigan toklar quyidagi formula yordamida aniqlanadi:
IDYU = A
IDP = A