77–
28
STATIC
ELECTRICITY
2000 Edition
FIGURE 8.6.2
Compression fitting for pneumatic transport
duct. (Pratt, 1997, p. 136.)
8.6.3
Use of nonconductive pipe or ductwork
is not recom-
mended. The use of short lengths of transparent plastic as flow
visualizers
is also not recommended, because they have been
known to give rise to propagating brush discharges capable of
igniting dusts.
8.7* Flexible Hoses.
Hoses made of nonconductive material
that incorporate a spiral stiffening
wire should be kept in good
repair to ensure that the internal wire directly contacts the
metal end couplings and that the end couplings make a good
connection to ground. Use of hoses with more than one inter-
nal
spiral is not recommended, because determining if one of
the spirals has lost its continuity is not possible.