Pharmaceutical Microbiology Manual
Download 1.15 Mb. Pdf ko'rish
|
ORA.007 Pharmaceutical Microbiology Manual
- Bu sahifa navigatsiya:
- Revised: 25 Aug 2020 Title: Pharmaceutical Microbiology Manual
F
OOD AND D RUG A DMINISTRATION O FFICE OF R EGULATORY A FFAIRS Office of Regulatory Science Document Number: ORA.007 Revision #: 02 Revised: 25 Aug 2020 Title: Pharmaceutical Microbiology Manual Page 38 of 92 For the most current and official copy, check QMiS. laboratory. The ORS laboratory protocol is summarized below for convenience. Perform medical device extractions and final endotoxin concentration calculations per USP <161> and USP <1085> Guidelines on the Endotoxins Test. Alternatively, if deemed necessary, perform the ORS laboratory modified extraction and analysis of Endotoxin from Medical Devices: a. Preparation of 1% SLS solution Prepare a 1% stock solution by placing one (1) gram of sodium lauryl sulfate (SLS) into a depyrogenated glass flask and add 99 ml of pyrogen-free water. Allow the SLS to fully dissolve. This should be followed by filtration through a 10,000 MW depyrogenation membrane filter into a pyrogen-free glass or plastic container. b. Equipment needed: Ultrasonic bath with a range of 150 to 480 watts. c. Extraction procedure i. Dilute 2mL of 1% SLS stock solution to 20mL (0.1%) using LAL reagent water in a 20 x 150 mm screw-cap tube. ii. Dilute 1.5mL of the 0.1% SLS solution to 15 mL (0.01%) using LAL reagent water in a 20 x 150 mm screw-cap tube. iii. Prepare the appropriate number of tubes (one tube for each device) and one as a negative / system control. Preheat in a water bath to 37°C ±1°C. iv. Aseptically remove the device from its packaging and cut it diagonally into pieces less than 5mm in length. Small metal and plastic pieces such as needles and luer-locks should be tested whole. Pyrogen-free fluid pathways should be flushed with extract solution. Note: Extract volume may need to be adjusted depending on medical device size. v. Place all pieces into the 20 x 150 mm tube containing 15 mL of preheated (37°C ±1°C) 0.01% SLS rinse solution. vi. Vortex the tubes for 30 – 60 seconds or until all pieces of the device are immersed in the rinse solution. vii. Sonicate the test containers for 60 minutes (wattage range 150 – 480 watts) at 37°C ±1°C. Do not sonicate more tubes than can be vortexed within 15 minutes of completion of the sonication. Make sure the water in the sonicator covers the |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling