4.11.4 Interpretation of Results. See Table C1 in Appendix C. If the test results are compared with those of 

tubes or sleeves, note that tapes are usually used with 50% overlap, i.e., double-layer. 



4.12 Resistance to Flame Propagation. Flame resistance will ensure that fire will not be spread by the tape on 

a wire harness. The test is to be performed on all adhesive harness tapes. 



4.12.1  Procedure.  The  test  is  performed  according  to  ISO 3795  and  FMVSS 302  on  a  wiring  harness  of 

seven (7) 1.0 mm

2

 cables wrapped with tape of 50% overlap. The insulating material used for the cables depends 



on the temperature class of the tape. See Table 4. The flame resistance will be rated according to Table 5. 

 

 



 

Copyright General Motors 

Provided by IHS Markit under license with General Motors

Order Number: W2199587

Sold to:MIRAKON [256916100001] - AZIMJON.KHOLOV@GMAIL.COM, 

Not for Resale,2020-01-07 15:49:58 UTC

Reproduction, distribution or publication of these standards is expressly prohib

--`,,,,``,,`,,,,,,`,,,``-`-``,```,,,`---