Navoiyazot” aj “pvx, ks va M” ishlab chiqarish majmuasi 910-sonli “Xlor, xlor mahsulotlari va kaustik soda” sexining
Download 0.92 Mb.
|
28.09.23регламент 04,09,23
4.3 TAQIQLAGICHLAR RO‘YXATI
Kaustik soda ishlab chiqarishining texnologik jarayonni xavfsiz olib borish maqsadida, avtomatik ravishda taqiqlagichlar ko‘zga tutilgan. 4.3.1 Birlamchi tuzli eritma olish (202-bino) 1. Poz.V220012 bakida (700 mm) minimal darajada poz.Р220004АВ nasoslarni o‘chirish (220LISАH,HHL,LL -03003). 2. Poz.V230001 bakida maksimal (7600 mm) darajada va minimal(1000 mm) darajada poz.Р220003АВ nasoslarni o‘chirish (230LIСSAH,HHL -01001). 3. Poz.V220015 temir uch xloridi tayyorlash bakida minimal (500 mm) darajada poz.Р220008 nasosni o‘chirish(LSAHL,LL-06004). 4. Poz.V220020 natriy karbonat tayyorlash bakida minimal (500 mm) darajada poz.Р220012 nasosni o‘chirish(LSAHL,LL-06005). 5. Poz.V220003 press filtr filtrat bakida minimal (950 mm)darajada poz.Р220007АВ nasoslarni o‘chirish (220LISАH,HHL,LL -07001). 6. Poz.V220022 bakida poz.Р220014 nasosini minimal (400 mm) darajada o‘chirish va maksimal (2400 mm) darajada yoqish (220LISАHL,LL -07003). 7. Poz.V220106 aylanam tuzli eritma bakidagi poz.Р220105АВ nasosini minimal (750 mm) darajada o‘chirishva maksimal (4250 mm) darajada yoqish (220LISAH,HHL,LL -09002). 8. Poz.V220105 bakida poz.Р220104АВ nasoslarni minimal (450 mm) darajada o‘chirish va maksimal (2550 mm) darajada yoqish(220LISAH,HHL,LL -09003). 9. Minimal (0,1 МРа) bosimda poz.Р220111 yuqori bosim nasosi, poz.Р220112 nasosi va poz.P220103А/В nasoslarini o‘chirish(220PISAL,LL-09003). 10. Poz.V220111bakida poz.Р220109АВ nasoslarni minimal (375 mm) darajada o‘chirishva maksimal (2125 mm) darajada yoqish. (220LISAH,HHL,LL -11001). 11. Poz.V220112 bakidagi matochniy eritmani aylanishini ta’minlash uchun poz.Р220110 nasosinio‘chirish va maksimal (1275 mm) darajada yoqish (220LISAH,HHL,LL -11002). 12. Poz.V220114 tuzsizlantirilgan suv bakida poz.Р220114 nasosiniminimal (945 mm) darajada o‘chirish va maksimal(2990 mm) darajada yoqish (220LISAH,HHL,LL -11003). 13. Poz.Р220111 yuqori bosim nasosi, poz.Р220112 nasosini va poz.Р220103А/В dastlabki tuzli eritma nasoslarini poz.V220104 bakida OQP (oksidlanish-qaytarilish potensiali) maksimal (100 mV) bo‘lganda o‘chirish(220AISAH,HH-09001). 14. Poz.Р220111 yuqori bosim nasosi, poz.Р220112 nasosini va poz.Р220103А/В dastlabki tuzli eritma nasoslarini poz.V220104 dastlabki tuzli eritma bakida Vodorod ko‘rsatkich pH qiymati minimal (5,5) maksimal (7,5) bo‘lganda o‘chirish(220AISAH,HHL,LL-09002). 4.3.2 Ikkilamchi tuzli eritma va elektroliz (203 bino) 1. Bug‘ kollektorida poz.E230001 demineralizatsiyalangan suv issiqlik almashtirgichidan chiqishda filtrlangan tuzli eritmaning harorati maksimal 70оСda 230TV-01001 klapanning yopilishi(230TICSAH,HHL-01001). 2. Poz.V230001 bakida darajasi maksimal (95 %) bo‘lganda poz.Р220003АВ tozalangan tuzli eritma nasosni o‘chirish(230LICSAH,HHL-01001). 3. Poz.V230003 rezervuarida maksimum (90 %) poz. Р230003 aylanma tuzli eritma nasosini o‘chirish va minimum (10%) poz. Р230003 aylanma tuzli eritma nasosini yoqish. (230LISAH,HHL,LL-01002). 4. Poz.V230004 tashlanma suvlar bakida maksimum (90%) darajada poz.Р230004 tashlanma suvlar nasosini o‘chirish va minimum (10 %) darajada poz.Р230004 tashlanma suvlar nasosini yoqish. (230LISAH,HHL,LL-03002). 5. Poz.R230101 qurilmaga kiradigan NO‘A va A havosining bosimi maksimal (0,4 МРа) bo‘lganda hamma rostlagichlarni o‘chirish (230PISAL,LL-03102). 6. Katolitning minimal 11,5 m3/h sarfida poz.R230101AВС elektrolizerlarga kirishda poz.R230101AВС elektrolizerlarning rostlagichlarni o‘chirish (230FICSAHL,LL-05001; 230FICSAHL,LL-07001; 230FICSAHL,LL-09001). 7. Poz.R230101AВС elektrolizerlarda kuchlanish farqlari maksimal (1,0 V) va minimal (-1,0V) bo‘lganda rostlagichlarni o‘chirish(230EDISAH,HHL,LL-05001; 230EDISAH,HHL,LL-07001; 230EDISAH,HHL,LL-09001). 8. Poz.R230101AВС elektrolizerlarga kirishda analitning minimal 5,2 m3/h sarfida poz.R230101AВС elektrolizerlarni rostlagichlarini o‘chirish (230FICSA HL,LL -05003; 230FICSA HL,LL -07003; 230FICSA HL,LL -09003). 9. Poz.R230101AВС elektrolizerlarda katod va anod gaz fazalari o‘rtasida bosimning minimal (-5,0 kPa) va maksimal (15 kPa) qiymatlarida poz.R230101AВС elektrolizerlarning rostlagichlarini o‘chirish (230PDISАH,HHL,LL-05002; 230PDISАH,HHL,LL-07002; 230PDISАH,HHL,LL-09002). 10.Poz. R230101AВС elektrolizerlarda maksimal (16,2 kA) tok bo‘lganda rostlagichlarni o‘chirish (230IISАH,HH-05001; 230IISАH,HH-07001; 230IISАH,HH-09001). 11. Nam xlorning asosiy quvurida maksimal bosim 30 kPa bo‘lganda poz.R230101 elektrolizerlardagi rostlagichlarni o‘chirish (230PISAН,НН-10001). 12. Poz.V230101 aylanma kuchsiz tuzli eritma bakidagi daraja maksimal (90%) bo‘lganda poz.R230101 elektrolizerdagi barcha rostlagichlarni o‘chirish. (230LICSAH,HHL-10001). 13. Nam xlorning asosiy quvurida maksimal bosim 30 kPa bo‘lganda poz.R230101 elektrolizerlardagi barcha rostlagichlarni o‘chirish(230PICSAH,HHL-10002). 14. H2/Cl2 asosiy quvuridagi bosim maksimal (9 kPa) va minimal (0 kPa) bo‘lganda poz.R230101 elektrolizerlardagi barcha rostlagichlarni o‘chirish(230PDISAH,HHL-10003). 15. Poz.V230102 aylanma ishqor eritma bakidagi daraja maksimal (90%) bo‘lganda poz.R230101 elektrolizerdagi barcha rostlagichlarni o‘chirish (230LICSAH,HHL-11001). 16. Nam xlorning asosiy quvurida maksimal bosim 34 kPa bo‘lganda poz.R230101 elektrolizerlardagi barcha rostlagichlarni o‘chirish (230PICSAH,HHL -11003). 17. Nam xlorning asosiy quvurida maksimal bosim (34 kPa) bo‘lganda poz.R230101 elektrolizerlardagi barcha rostlagichlarni o‘chirish (230PISAН,НН-11004). 18. Poz. V230105 elektrolizdan keyingi kuchsiz tuzli eritma bakidagi darajasi maksimal (50%) yoqish va minimal (10%) bo‘lganda poz.Р230104 nasosini o‘chirish (230LISAHL-12001). 19. Poz. V230106 elektrolizdan keyingi (20%) ishqor bakidagi darajasi maksimal (80 %) bo‘lganda yoqish va minimal (5%) bo‘lganda poz.Р230106 nasosini o‘chirish (230LISAH,HHL,LL-12002). 20. Poz. E230104 issiqlik almashtirgichdan chiqishda kuchsiz tuzli eritmaning harorati maksimal (110оС) bo‘lganda bug‘ kollektoriga kiruvchi 230TV-14001 klapanning yopilishi(230TICSAH,HHL-14001). 21. Poz.Е230104 issiqlik almashtirgichga kuchsiz tuzli eritmaning kirishida sarfning minimal miqdorida (2,4 m3/h) 230FV-14001 va 230FV-14002 klapanlarining yopilishi(230FICSAHL,LL-14002). 22. Poz.T230201 xlor ajratish kollonasining maksimal darajasida (90 %) 230LV-10001 klapanlarining yopilishi. (230LICSAH,HHL-15001). 23. Poz. V230203230 separatordagi minimal (15 %) daraja bo‘lganda ochilishi va maksimal (85 %) darajada bo‘luvchi klapanning yopilishi (LICSAH,HHL,LL-15010). 4.3.3 Xlor va vodorodni qayta ishlash (204 bino) 1. Poz.V240001 xlor gazining gidrozatvor depressivminimal darajada (25 %) ochilishi va maksimal (85%)darajada yopilishi, poz.240XV-01001 birlamchi tuzsizlantirilgan suv quvuridagi ochuvchi-yopuvchi klapanining yopilishi (240LISAHL-01003). 2. Poz.V240002 kuchsiz sulfat kislota rezervuarida poz.Р240004 nasosni minimal darajada (600 mm) yoqish va maksimal (2400 mm) darajada o‘chirish(240LISAHL,LL-03004). 3. Poz.V240004 konsentrlangan sulfat kislota rezervuarida poz.Р240005 nasosni minimal darajada (10 %) yoqish va maksimal (95 %) darajada o‘chirish (240LISAH,HHL,LL-03005). Bundan tashqari, konsentrlangan sulfat kislota poz.Р2900002 nasosini minimal darajada (10 %) yoqish. 4. Poz.V240006 bakidagi poz.Р240006 nasosni minimal darajada (600 mm) o‘chirish va maksimal (2200 mm) darajada yoqish(240LISAH,HHL,LL-05002). 5. Poz.V240102 bakidagi poz.Р240102 nasosni minimal darajada (400 mm) o‘chirish vamaksimal darajada (2300 mm) yoqish (240LISAHL,LL-06002). 6. Vodorod (Н2)bo‘yicha ishchi hudud havosining tahlili Vodorodning maksimal (50 %) bo‘lganda yutuvchi poz. EF204201 ÷ EF204204 ventilyatorlarini yoqish (240GISAH-01001 ÷ 01007). 7. Xlor (Сl2) bo‘yicha ishchi hudud havosining tahlili Xlorning maksimal (2 ppm) bo‘lganda yutuvchi poz. EF204201 ÷ EF204204 ventilyatorlarini yoqish (240GISAH-01001 ÷ 01003). 4.3.4 Xlorni suyultirish. Ishga tushirish davri uchun suyuq xlorni bug‘latish qurilmalarida saqlash. (205-bino) 1. Poz. V250001AВС suyuq xlor rezervuaridagi 250XV-04001АВС bo‘luvchi klapanni maksimal darajada(70 %) yopilishi (250LISAH,HHL-04001AВС). 2. Poz.V250001АВС rezervuaridagi daraja minimal bo‘lganda poz.Р250001АВС nasosini o‘chirish (250LISAHLL-04002AВС). 3. Poz.Р250001АВ suyuq xlor nasosining chiqishidagi maksimal bosim (1,05 МРа) bo‘lganda poz.Р250001АВ nasosini o‘chirish (250PISAН,НН-05002). 4. Poz.V250008 sulfat kislotani saqlash rezervuaridagi minimal (10 %)da ochilishi va maksimal (80%)da 250XV-06001 klapanning yopilishi (250LISAH,HHL-06006). 5. Sulfat kislota separatoridagi minimal (15 %) darajada yonishi va maksimal (80 %) darajada poz. Р250003 nasosni o‘chirish (250LISAH,HHL,LL-06010). 6. Poz.V250015 tashlanma suvlar basseynida daraja minimal (5%) bo‘lganda poz.Р250007 nasosini o‘chirish(250LISAHL-09001). 7. Poz.V250015 tashlanma suv basseynida maksimal qiymati рН=6,5 bo‘lganda 32% ishqor beruvchi poz.250XV-09001 ochib-yopuvchi klapanning yopilishi (250AISAH-09001). 8. Zaharli gazlar datchigi signal berganda tortib oluvchi ventilyatorni yoqish va poz.250XV-09002 suv sachratuvchi yopuvchi klapanning ochilishi. 4.3.5 5 Vodorod xlorid sintezi va yuqori toza xlorid kislota ishlab chiqarish (206-bino) 1. Poz.V260002 xlorning bufer rezervuaridan chiqishdagi xlor gazining harorati (40-45) оСTuzatish impulsi 260FIC-01002, 260FIC-02002, 260FIC-03002 (260TISAHL-01001). 2. Poz.R260001A vodorod xlorid sintezi pechida olov o‘chirilganda(ВSAL-01001): 1) Poz.R260001Аvodorod xlorid sintezi pechini to‘xtatish Pechni to‘xtatgan vaqtdaquyidagilar ishga tushishi kerak: a) Poz.R260001Аvodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-01001 nazorat klapanining yopilishi; b) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002 nazorat klapanining yopilishi; C) Poz.R260001А vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260ХV-01001 chiqish klapanining yopilishi; D) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260ХV-01002 chiqib ketish klapanini yopilishi; e) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260ХV-01003 chiqib ketish klapanini yopish; f) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260ХV-01004 chiqib ketish klapanini yopish; g) Poz.R260001Аvodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260ХV-01005 chiqib ketish klapanining ochilishi. 3. Poz.R260001A vodorod xlorid sintezi pechida alanga o‘chganda, (ВSAL-01002): 1)Poz.R260001A vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) poz.R260001Аvodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-01001 nazorat klapanining yopish; b) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002 nazorat klapanining yopish; c) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001 chiqib ketish klapanini yopish; d) Poz.R260001A klapanining yopish; e)Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002 chiqib ketish klapanini yopish; f) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida(baypass) 260ХV-01003 chiqib ketish klapani va xlor liniyasida (bypass) 260ХV-01004 chiqib ketish klapani yopish; g)Poz.R260001Аvodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-01005 chiqib ketish klapanining ochish. 4. Poz. R260001B vodorod xlorid sintezi pechida alanga o‘chganda, (ВSAL-02001): 1)Poz.R260001B vodorod xlorid sintezi pechini to‘xtatish.Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001Вvodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-02001 nazorat klapanining yopish; b) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-02002 nazorat klapanining yopish; c) Poz.R260001B vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-02001 chiqib ketish klapanini yopish; d) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-02002 chiqib ketish klapanini yopish; e) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (bypass) 260XV-02003 chiqib ketish klapanini yopish; f) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-02004 chiqib ketish klapanini yopish; g)Poz.R260001Вvodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-02005 chiqib ketish klapanining ochish. 5. Poz.R260001B vodorod xlorid sintezi pechida alanga o‘chganda, (ВSAL-02002): 1)Poz.R260001B vodorod xlorid sintezi pechining to‘xtashi. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001В vodorod xlorid sintez pechining kirish qismidagi vodorod liniyasida 260 FV-02001 nazorat klapanining yopilishi; b) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-02002 nazorat klapanining yopilishi; C) Poz.R260001B vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-02001chiqib ketish klapanini yopilishi; D) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-02002 chiqib ketish klapanini yopish; e) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-02003 chiqib ketish klapanini yopish; f) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-02004 chiqib ketish klapanini yopish; g)Poz.R260001Вvodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-02005 chiqib ketish klapanining ochilishi. 6. Poz.R260001C vodorod xlorid sintezi pechida alanga o‘chganda (ВSAL-03001): 1)Poz. R260001C vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a)Poz.R260001Сvodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-03001 nazorat klapanining yopilishi; b) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-03002 nazorat klapanining yopilishi; C) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-03001 chiqib ketish klapanini yopish; D) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-03002 chiqib ketish klapanini yopish; e) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-03003 chiqib ketish klapanini yopish; f) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-03004 chiqib ketish klapanini yopish; g)Poz .R260001Сvodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-03005 chiqib ketish klapanining ochilishi. 7. Poz.R260001C vodorod xlorid sintezi pechida alanga o‘chganda (ВSAL-03002): 1) Poz. R260001C vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a)Poz.R260001Сvodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-03001 nazorat klapanining yopilishi; b) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-03002 nazorat klapanining yopilishi; C) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-03001chiqib ketish klapanini yopish; D) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-03002 chiqib ketish klapanini yopish; e) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-03003 chiqib ketish klapanini yopish; f) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-03004 chiqib ketish klapanini yopish; g)Poz.R260001Сvodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-03005 chiqib ketish klapanining ochilishi. 8. Poz.R260001A vodorod xlorid sintezi pechini yoqish (yoqish) uchun ruxsat beruvchi signal-faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-01001, 260FV-01002 2) chiqib ketish klapanlarini yopish 260X V-01001, 260XV-01002,260ХV-01003, 260XV-01004, 260XV-01005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-01003, 260FIQSAH-01005 , 260FIQSAH-01006 (260UST-01001). 9. Poz.R260001B vodorod xlorid sintezi pechini yoqish (yoqish) uchun ruxsat beruvchi signal- faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) klapanlarning yopilishini tartibga soluvchilar 260FV-02001, 260FV-02002 2) chiqib ketish klapanlarini yopish 260XV-02001, 260XV-02002,260ХV-02003, 260XV-02004, 260XV-02005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-02003, 260FIQSAH-02005 , 260FIQSAH-02006(260UST-02001). 10. Poz.R260001C vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-03001, 260FV-03002 2) chiqib ketish klapanlarini yopish 260XV-03001, 260XV-03002, 60xV-03003, 260XV-03004, 260XV-03005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-03003, 260FIQSAH-03005, 260FIQSAH-03006(260UST-03001). 11. Poz.V260003А bug‘ning bir zumda qaynash bakidagi daraja minimal 300 mm bo‘lganda (260LICSAHL,LL-01003): 1) Poz.R260001A vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001Avodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-01001 nazorat klapanining yopilishi; b) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002 nazorat klapanining yopilishi; C) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001chiqib ketish klapanini yopish; D) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002 chiqib ketish klapanini yopish; e) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-01003 chiqib ketish klapanini yopish; f) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-01004 chiqib ketish klapanini yopish; g) Poz.R260001Avodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-01005 chiqib ketish klapanining ochilishi. Poz.V260003А bug‘ning bir zumda qaynash bakidagi daraja maksimal 800 mm bo‘lganda: Poz.R260001A vodorod xlorid sintezi pechini yoqish- faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-01001, 260FV-01002 2) chiqib ketish klapanlarini yopish 260XV-01001, 260XV-01002, 260XV-01003, 260XV-01004, 260XV-01005 3) texnologik ko‘rsatkichlar bo‘yicha 260 PICSA H-01009, 260 PICSA H-01010, 260 PIS H-01020, 260 PISA H-04004, 260 LICSA H-01003, 260 FIQSA H-01005, 260 FIQSA H-01006 12. Poz.R260001A vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida minimal oqim tezligi (80 m3/h) bo‘lganda (260FIQSA H L-01005): 1) Poz.R260001A vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a)Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-01001 nazorat klapanining yopilishi; b) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002 nazorat klapanining yopilishi; C) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001chiqib ketish klapanini yopish; D) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002 chiqib ketish klapanini yopish; e) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-01003 chiqib ketish klapanini yopish; f) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-01004 chiqib ketish klapanini yopish; g) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-01005 chiqib ketish klapanini ochish. Poz.R260001A vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida maksimal oqim tezligi (100 m3/h) bo‘lganda Poz.R260001A vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-01001, 260FV-01002 2) chiqib ketish klapanlarini yopish 260XV-01001, 260XV-01002, 260XV-01003, 260XV-01004, 260XV-01005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-01003, 260FIQSAH-01005, 260FIQSAH-01006 13. Poz.R260001A vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida minimal oqim tezligi (30 m3/h) bo‘lganda (260FIQSАHL-01006): 1) Poz.R260001A vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a)Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-01001 nazorat klapanining yopilishi; b) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002 nazorat klapanining yopilishi; C) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001chiqib ketish klapanini yopish; D) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002 chiqib ketish klapanini yopish; e) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-01003 chiqib ketish klapanini yopish; f) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-01004 chiqib ketish klapanini yopish; g) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida.260XV-01005 chiqib ketish klapanini ochish. Poz.R260001A vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida maksimal oqim tezligi (40 m3/h) bo‘lganda: Poz.R260001A vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-01001, 260FV-01002 2) chiqib ketish klapanlarini yopish 260XV -01001,260ХV-01002,260ХV-01003, 260XV-01004, 260XV-01005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-01003, 260FIQSAH-01005, 260FIQSAH-01006 14. Poz.V260003B bug‘ning bir zumda qaynash bakidagi daraja minimal 300 mm bo‘lganda (260LICSAHL,LL-02003): 1) Poz.R260001B vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001В vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-02001 nazorat klapanining yopilishi; b) ) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-02002 nazorat klapanining yopilishi; C) ) Poz.R260001В vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-02001 chiqib ketish klapanini yopish; D) ) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-02002 chiqib ketish klapanini yopish; e) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-02003 chiqib ketish klapanini yopish; f) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-02004 chiqib ketish klapanini yopish; g) Poz.R260001В vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-02005 chiqib ketish klapanining ochilishi. Poz.V260003B bug‘ning bir zumda qaynash bakidagi daraja maksimal 800 mm bo‘lganda: Poz.R260001B vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-02001, 260FV-02002 2)chiqib ketish klapanlarini yopish 260XV-02001,260ХV-2002,260ХV-02003, 260XV-02004, 260XV-02005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-02003, 260FIQSAH-02005, 260FIQSAH-02006 15. Poz.R260001B vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida minimal oqim tezligi (80 m3/h) bo‘lganda (260FIQSA H L-02005): 1) Poz.R260001B vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001B vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260FV-02001 nazorat klapanining yopilishi; b) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-02002 nazorat klapanining yopilishi; C) Poz.R260001B vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-02001 chiqib ketish klapanini yopish; D) Poz.R260001Bvodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-02002 chiqib ketish klapanini yopish; e) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-02003 chiqib ketish klapanini yopish; f) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-02004 chiqib ketish klapanini yopish; g) Poz.R260001B vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-02005 chiqib ketish klapanini ochish. Poz.R260001B vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida maksimal oqim tezligi (100 m3/h) bo‘lganda Poz.R260001B vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-02001, 260FV-02002 2) chiqib ketish klapanlarini yopish 260XV-02001,260ХV-02002,260ХV-02003, 260XV-02004, 260XV-02005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009,260PICSAH-01010, 260PISH-01020,260PISAH-04004, 260LICSAH-02003, 260FIQSAH-02005, 260FIQSAH-02006 16. Poz.R260001B vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida minimal oqim tezligi (30 m3/h) bo‘lganda (260FIQSA H L-02006): 1) Poz.R260001B vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001В vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-02001 nazorat klapanining yopilishi.; b) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-02002 nazorat klapanining yopilishi; C) Poz.R260001В vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-02001 chiqib ketish klapanining yopilishi; D) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-02002 chiqib ketish klapanini yopish; e) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-02003 chiqib ketish klapanini yopish; f) Poz.R260001В vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-02004 chiqib ketish klapanini yopish; g) Poz.R260001В vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-02005 chiqib ketish klapanini ochish. Poz.R260001B vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida maksimal oqim tezligi (40 m3/h) bo‘lganda: Poz.R260001B vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-02001, 260FV-02002 2) chiqib ketish klapanlarini yopish 260XV-02001, 260XV-02002, 260XV-02003, 260XV-02004, 260XV-02005 3) texnologik ko‘rsatkichlar bo‘yicha 260 PICSA H-01009, 260 PICSA H-01010, 260 PIS H-01020, 260 PISA H-04004, 260 LICSA H-02003, 260 FIQSA H-02005, 260 FIQSA H-0200 17. Poz.V260003C bug‘ning bir zumda qaynash bakidagi daraja minimal 300 mm bo‘lganda (260LICSAHL,LL-03003): 1) Poz.R260001C vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a)Poz.R260001Cvodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-03001 nazorat klapanining yopilishi.; b) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-03002 nazorat klapanining yopilishi; C) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-03001chiqib ketish klapanini yopish; D) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-03002 chiqib ketish klapanini yopish; e) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-03003 chiqib ketish klapanini yopish; f) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-03004 chiqib ketish klapanini yopish; g) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-03005 chiqib ketish klapanini ochish. Poz.V260003C bug‘ning bir zumda qaynash bakidagi daraja maksimal 800 mm bo‘lganda: Poz.R260001C vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-03001, 260FV-03002 2) chiqib ketish klapanlarini yopish 260XV-03001,260ХV-03002,260ХV-03003, 260XV-03004, 260XV-03005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009,260PICSAH-01010, 260PISH-01020,260PISAH-04004, 260LICSAH-03003, 260FIQSAH-02005, 260FIQSAH-02006 18. Poz.R260001C vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida minimal oqim tezligi (80 m3/h) bo‘lganda (260FIQSA H L-03005): 1) Poz.R260001C vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001С vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-03001 nazorat klapanining yopilishi; b) sintez pechining kirish qismida xlor liniyasida 260FV-03002 nazorat klapanining yopilishi; e) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-03003 chiqib ketish klapanini yopish; f) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-03004 chiqib ketish klapanini yopish; g) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-03005 chiqib ketish klapanini ochish. Poz.R260001C vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida maksimal oqim tezligi (100 m3/h) bo‘lganda: Poz.R260001A vodorod xlorid sintezi pechini yoqish uchun ruxsat beruvchi signal - faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-03001, 260FV-03002 2) chiqib ketish klapanlarini yopish 260XV-03001, 260XV-03002, 260XV-03003, 260XV-03004, 260XV-03005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-03003, 260FIQSAH-03005, 260FIQSAH-03006 19. Poz.R260001C vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida minimal oqim tezligi (30 m3/h) bo‘lganda (260FIQSA H L-03006): 1) Poz.R260001C vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a)Poz.R260001С vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260 FV-03001 nazorat klapanining yopilishi; b) Poz.R260001С vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-03002 nazorat klapanining yopilishi; C) Poz.R260001С vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-03001chiqib ketish klapanini yopish; D) Poz.R260001С vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-03002 chiqib ketish klapanini yopish; e) Poz.R260001С vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-03003 chiqib ketish klapanini yopish; f) Poz.R260001С vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-03004 chiqib ketish klapanini yopish; g) Poz.R260001С vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-03005 chiqib ketish klapanini ochish. Poz.R260001C vodorod xlorid sintezi pechining teskari aylanma suvining chiqishida maksimal oqim tezligi (40 m3/h) bo‘lganda: Poz.R260001C vodorod xlorid sintezi pechini yoqish faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-03001, 260FV-03002 2) chiqib ketish klapanlarini yopish 260XV-03001, 260ХV-03002, 260ХV-03003, 260XV-03004, 260XV-03005 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-03003, 260FIQSAH-03005, 260FIQSAH-03006 20. Yorilish membranasining portlash bosimi (260PSAH-01001) Maksimal bosim ostida: 1) Poz.R260001A vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260FV-01001 nazorat klapanining yopilishi; b) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002 nazorat klapanining yopilishi; C) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001chiqib ketish klapanini yopish; D) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002 chiqib ketish klapanini yopish; e) Poz.R260001Avodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-01003 chiqib ketish klapanini yopish; f) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-01004 chiqib ketish klapanini yopish; g) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-01005 chiqib ketish klapanini ochish. 21. Poz.V260002 vodorod bufer rezervuaridan chiqishda vodorod harorati (40÷45)0C. Tuzatish impulslari 260FIC-01001, 260FIC-02001 va 260FIC-03001 (260TISAHL-01002). 22. Poz.V260002 xlor bufer rezervuaridagi xlor gazining maksimal bosimi (150 kPa) (260PICSAHL-01009): Poz.R260001ABC vodorod xlorid sintezi pechini yoqish faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-01001(260FV-02001, 260FV-03001), 260FV-01002 (260FV-02002, 260FV-03002) 2) chiqib ketish klapanlarini yopish 260XV-01001 (260XV-02001, 260XV-03001), 260XV-01002 (260XV-02002, 260XV-3002), 260XV-01003 (260XV-02003, 260XV-03003), 260XV-01004 (260XV-02004, 260XV-03004), 260XV-01005 (260XV-02005, 260xV-03005) 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-01003(260LICSAH-02003, 260LICSAH-03003), 260FIQSAH-01005 (260FIQSAH-02005, 260FIQSAH-03005), 260FIQSAH-01006 (260FIQSAH-02006, 260FIQSAH-03006) 23. Poz.V260001 vodorodning bufer rezervuaridagi maksimal bosim (90 kPa) bo‘lganda (260PICSAHL-01010): Poz.R260001ABC vodorod xlorid sintezi pechini yoqish faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-01001(260FV-02001, 260FV-03001), 260FV-01002 (260FV-02002, 260FV-03002) 2) chiqib ketish klapanlarini yopish 260XV-01001 (260XV-02001, 260XV-03001), 260XV-01002 (260XV-02002, 260XV-3002),260ХV-01003 (260XV-02003, 260XV-03003), 260XV-01004 (260XV-02004, 260XV-03004), 260XV-01005 (260XV-02005, 260xV-03005) 24. Poz.V260001 vodorod bufer rezervuarining chiqishidagi vodorodning minimal bosimida (60 kPa) (260PIRBilanSAHL,LL-01011): 1) Poz.R260001ABC vodorod xlorid sintezi pechini yoqish faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: a) Poz.R260001ABC vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260FV-01001, 260FV-02001, 260FV-03001 nazorat klapanlarini yopish; b) Poz.R260001ABC vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002, 260FV-02002, 260FV-03002 nazorat klapanlarini yopish. 3) texnologik ko‘rsatkichlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-01003 (260LICSAH-02003, 260LICSAH-03003), 260FIQSAH-01005 (260FIQSAH-02005, 260FIQSAH-03005), 260FIQSAH-01006 (260FIQSAH-02006, 260FIQSAH-03006) C) Poz.R260001ABC vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001, 260XV-02001, 260XV-03001 chiqib ketish klapanlarini yopish; D) Poz.R260001ABC vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002, 260XV-02002, 260XV-03002 chiqib ketish klapanlarini yopish. e) Poz.R260001ABCvodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-01003, 260XV-02003, 260XV-03003 chiqib ketish klapanlarini yopish. f) Poz.R260001ABC vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-01004, 260XV-02004, 260XV-03004 chiqib ketish klapanlarini yopish. g) Poz.R260001ABC vodorod xlorid sintezi pechining kirish qismida azot liniyasida 260XV-01005 chiqib ketish klapanlarini ochish. 25. Poz.V260002 xlor bufer rezervuarining chiqishidagi xlor gazining minimal bosimida (100 kPa) (260PIRCSAHL,LL-01012): 1) Poz.R260001ABC vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001ABC vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260FV-01001, 260FV-02001, 260FV-03001 nazorat klapanlarini yopish. b)Poz. R260001ABC vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002, 260FV-02002, 260FV-03002 nazorat klapanlarini yopish. C) Poz. R260001ABC vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001, 260XV-02001, 260XV-03001 chiqib ketish klapanlarini yopish. D) Poz. R260001ABC vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002, 260XV-02002, 260XV-03002chiqib ketish klapanlarini yopish. e) Poz. R260001ABC vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-01003, 260XV-02003, 260XV-03003 chiqib ketish klapanlarini yopish. f) Poz. R260001ABC vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-01004, 260XV-02004, 260XV-03004 chiqib ketish klapanlarini yopish g) Poz. R260001ABC vodorod xlorid sintezi pechining kirish qismida azot liniyasida 260XV-01005 chiqib ketish klapanlarini ochish. 26. Poz.R260001A vodorod xlorid poz vodorod xlorid sintezi pechining chiqishida maksimal bosimida (80 kPa) (260PICSAH-01013): 1) Poz.R260001A vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001A vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260FV-01001nazorat klapanining yopilishi. b) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-01002 nazorat klapanining yopilishi. c) Poz.R260001Avodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-01001chiqib ketish klapanini yopish. d) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002 chiqib ketish klapanini yopish. D) Poz.R260001Avodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-01002 chiqib ketish klapanini yopish. e) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-01003 chiqib ketish klapanini yopish. f) Poz.R260001A vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-01004 chiqib ketish klapanini yopish. g) Poz.R260001Avodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-01005 chiqib ketish klapanini ochish. 27. Yorilish membranasining maksimal portlash bosimida (260PSAH-02001): 1) Poz.R260001B vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a)Poz. R260001B vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260FV-02001 nazorat klapanining yopilishi. b) Poz.R260001B vodorod xlorid sintezi pechning kirish qismidagi xlor liniyasida 260FV-02002 nazorat klapanining yopilishi. C) Poz.R260001B vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-02001chiqib ketish klapanini yopish. D) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-02002 chiqib ketish klapanini yopish. e) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-02003 chiqib ketish klapanini yopish. f) Poz.R260001B vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-02004 chiqib ketish klapanini yopish. g) Poz.R260001B vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-02005 chiqib ketish klapanini ochish. 28. Yorilishi membranasining maksimal bosimida (0,7 MPa) portlashi (260PSAH-03001): 1) Poz.R260001C vodorod xlorid sintezi pechini to‘xtatish. Pech to‘xtatilganda, bir vaqtning o‘zida quyidagilar ishga tushishi kerak: a) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260FV-03001 nazorat klapanining yopilishi. b) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260FV-03002 nazorat klapanining yopilishi. C) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi vodorod liniyasida 260XV-03001chiqib ketish klapanini yopish. D) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida 260XV-03002 chiqib ketish klapanini yopish. e) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida vodorod liniyasida (baypass) 260XV-03003 chiqib ketish klapanini yopish. f) Poz.R260001C vodorod xlorid sintezi pechining kirish qismida xlor liniyasida (baypass) 260XV-03004 chiqib ketish klapanini yopish. g) Poz.R260001C vodorod xlorid sintezi pechining kirish qismidagi azot liniyasida 260XV-03005 chiqib ketish klapanini ochish. 29. Poz.P260005A/B tuzsizlantirilgan suv nasoslaridan keyin birlamchi tuzsizlangan suvning maksimal bosimida (260PISAHL -04004): Poz.R260001ABC vodorod xlorid sintezi pechini yoqish faqat quyidagilar bir vaqtning o‘zida ishga tushirilganda ruxsat beriladi: 1) nazorat klapanlarini yopish 260FV-01001(260FV-02001, 260FV-03001), 260FV-01002 (260FV-02002, 260FV-03002) 2) chiqib ketish klapanlarini yopish 260XV-01001 (260XV-02001, 260XV-03001), 260XV-01002 (260XV-02002, 260XV-3002), 260XV-01003 (260XV-02003, 260XV-03003), 260XV-01004 (260XV-02004, 260XV-03004), 260XV-01005 (260XV-02005, 260xV-03005) 3) texnologik parametrlar bo‘yicha 260PICSAH-01009, 260PICSAH-01010, 260PISH-01020, 260PISAH-04004, 260LICSAH-01003 (260LICSAH-02003, 260LICSAH-03003), 260FIQSAH-01005 (260FIQSAH-02005, 260FIQSAH-03005), 260FIQSAH-01006 (260FIQSAH-02006, 260FIQSAH-03006) 4.3.6 Bug‘latish va qattiq kaustik soda olish (207 bino) 1. Poz.V270001 xom ishqorni saqlash idishida maksimal darajada (≥ 90%)270LV-01001klapanini yopish.(270LICSAH,HHL,LL-01001). 2. Poz.V270001 xom ishqorni saqlash uchun idishda minimal darajada (≤ 10%) poz.P270004A/B 32% ishqor nasosini o‘chirish. (270LICSAH,HHL,LL-01001). 3. Pos.P270004AB 32% ishqor nasosining ishlamay qolishi. Nasosning favqulodda to‘xtash signalizatsiyasi. Poz.E270001 bug‘latgichning kirish qismidagi bug‘ kollektorida 270FV-04005 klapanining yopilishi, 32% ishqor oqimini qo‘lda tartibga solish uchun 270FV-02002 klapanini ochish, nasos to‘liq to‘xtatilganda xom ishqor darajasini tartibga solish uchun 270LV-01001 klapanini yopish (270USA-01001AC). 4. Poz.P270003AB36% ishqor nasosning ishlamay qolishi. Nasosning favqulodda to‘xtash signalizatsiyasi. Poz.E270001 bug‘latgichning kirish qismidagi bug‘ kollektorida 270FV-04005 klapanining yopilishi, nasos to‘liq to‘xtaganda poz.E270003 bug‘latgichda darajani tartibga solish uchun 270LV-02006 klapanini ochish (270USA-02001AB). 5. Poz.E270001 bug‘latgichning kirishdagi bug‘ kollektorida maksimal (≥26 m3/h) va poz.E270003 32% ishqor bug‘latgichining kirishdagi minimal (≤ 8 m3/h)sarfida 270FV-04005 klapanini yopish (270FQICSAH,HHL,LL-02002). 6. Poz.E270003 bug‘latgichga 32% ishqor kirishida maksimal sarfi (≥26 m3/h) bo‘lganda poz.P270004A nasosni o‘chirish (270FQICSAH,HHL,LL-02002). 7. Poz.E270001 bug‘latgichning kirish qismidagi bug‘ kollektorida 270FV-04005 klapanining yopilishi, bug‘latgichda darajani tartibga solish uchun poz.270LV-02006 klapanini ochish, poz.E270003 bug‘latgichda maksimal darajada (≥90%) bo‘lganda poz.P270004AB 32% ishqor nasosini o‘chirish (270LSHH-02005). 8. Poz.E270001 bug‘latgichning kirish qismidagi bug‘ kollektorida 270FV-04005 klapanining yopilishi, bug‘latgichda darajani tartibga solish uchun poz.270LV-02006 klapanini ochish, poz.E270003 bug‘latgichda maksimal darajada (≥90%) bo‘lganda poz.P270004AB 32% ishqor nasosini o‘chirish (270LICSAH,HHL,LL-02006). 9. Poz.E270001 bug‘latgichning kirish qismidagi bug‘ kollektorida 270FV-04005 klapanining yopilishi, poz.E270003 bug‘latgichda minimal darajada (≥10%) bo‘lganda poz.P270004AB 36% ishqor nasosini o‘chirish (270LICSAN,NNL,LL-02006). 10. Poz.E270003 bug‘latgichdan chiqishdagi 36% ishqorning maksimal (25 m3/h) va minimal (7,5 m3/h) sarfidapoz.E270001 bug‘latgichning kirish qismidagi bug‘ kollektoridagi 270FV-04005 klapaning yopilishi (270FQISAH,HHL,LL-02014). 11. Poz.E270003 bug‘latgichdan chiqishida 36% maksimal (25 m3/h) sarfida poz.P270003AB 36% ishqor nasosini o‘chirish(270FQISAH,HHL,LL-02014). 12. Poz.P270002AB 42% ishqor nasosining ishlamay qolishi. Nasosning favqulodda to‘xtash signalizatsiyasi. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi 270FV-04005 klapanining yopilishi, nasos to‘liq to‘xtatilganda poz.E270002bug‘latgichdagi darajani tartibga soluvchi 270LV-03003 klapanning ochilishi (270USA-03001AC). 13. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi poz.270FV-04005 klapanining yopilishi, bug‘latgichdagidarajani tartibga soluvchi poz.270LV-03003 klapanining ochilishi. Poz.Е270002 bug‘latgichda maksimal darajada (≥90 %) bo‘lganda poz.P270003A/B 36% ishqor nasosini o‘chirish (270LSHH-03002). 14. . Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi poz.270FV-04005 klapanining yopilishi, bug‘latgichdagi darajani tartibga soluvchi poz.270LV-03003 klapanining ochilishi,poz.Е270002 bug‘latgichda maksimal darajada (≥90 %) bo‘lganda poz.P270003A/B 36% ishqor nasosini o‘chirish(270LICSAН,ННL,LL-03003). 15. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi poz.270FV-04005 klapanining yopilishi, poz.Е270002 bug‘latgichda minimal darajada (≤10%) bo‘lganda poz.P270003A/B 42% ishqor nasosini o‘chirish (270LICSAH,HHL,LL-03003). 16. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi poz.Е270002 bug‘latgichdan chiqishda 42% ishqorning maksimal (>20 m3/h) va minimal (<6.5 m3/h ) sarfida poz.270FV-04005 klapanining yopilishi (270FQISAH,HHL,LL-03011). 17. Poz.Е270002 bug‘latgichdan chiqishda 42% ishqorning sarfi maksimal darajada (>20 m3/h) bo‘lganda poz.P270002AB 42% ishqor nasosini o‘chirish(270FQISAH,HHL,LL-03011). 18. Poz.P270001AB 50% ishqor nasosning ishlamay qolishi. Nasosning favqulodda to‘xtash signalizatsiyasi. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi 270FV-04005 klapanining,nasos to‘liq to‘xtaganda poz.E270001 bug‘latgich darajasini tartibga soluvchi 270LV-05007 klapanning ochilishi (270USA-04001AB). 19. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi poz.270FV-04005 klapanining yopilishi, poz.E270001 bug‘latgichda 50% ishqor maksimal darajada (≥90 %) bo‘lganda poz.P270002AB 42% ishqor nasosini o‘chirish(270LSNN-04004). 20. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi poz.270FV-04005 klapanining yopilishi, bug‘latgichda darajani tartibga solish uchun poz. 270LV-05007 klapanini ochish, poz.E270001 bug‘latgichda 50% ishqorningmaksimal darajada (≥90 %)da poz.P270002AB 42% ishqor nasosini (270LICSAH,HHL,LL-04016 ). 21. Poz.E270001 bug‘latgichga kirishda bug‘ kollektoridagi poz.270FV-04005 klapanining yopilishi, poz.E270001 bug‘latgichda 50% ishqorning minimal darajada (≤ 10%)da poz.P270001AB 50% ishqor nasosini o‘chirish. (270LICSAH,HHL,LL-04016). 22. Poz.V270004 bakidagi minimal darajada (≤ 10%) poz.P270006AB kondensatsiyalanadigan suv nasosini o‘chirish (270LICSAHL,LL-06001). 23.Poz.E270014 oxirgi konsentratorga kirishda ishqor suyuqligi kollektoridagi 270FV-08001 klapanning ochilishi, poz.E270011 dastlabki konsentratordagi darajani nazorat qilish, maksimal darajada (≥90%) bo‘lganda poz.270LV-07010 klapanini yopish (270LSHH-07009). 24. Poz.E270014 oxirgi konsentratorga kirishda ishqor suyuqligi kollektoridagi 270FV-08001 klapanning ochilishi, poz.E270011 dastlabki konsentratordagi maksimal darajada (≥90%) bo‘lganda poz.270LV-07010 klapanini yopish ( (270LICSAH,HHL,LL-07010). 25. Poz.E270014 oxirgi konsentratorga kirishda ishqor suyuqligi kollektoridagi 270FV-08001 klapanning ochilishi, poz.E270011 dastlabki konsentratordagi minimal darajada (≤ 10%) bo‘lgandapoz.P270007AB 61% ishqor nasosini o‘chirish (270LICSAH,HHL,LL-07010). 26. Poz.E270014 oxirgi konsentratorga kirishda 61% ishqor quvurida 1,5 m3/h minimal sarfida poz.270FV-08001 klapanini ochish (270FQISCAHL,LL-08001). 27. Poz.CA270001 havo puflagichning ishlamay qolishi. Havo puflagichining favqulodda to‘xtash signalizatsiyasi. Poz.P270011 nasos to‘xtaganda poz.BG270001 yoqgichni o‘chirish (270USA-10001). 28. Poz.P2700011 eritilgan tuz nasosining ishlamay qolishi. Favqulodda to‘xtash signalizatsiyasi. Nasos to‘xtaganda poz.BG270001 yoqgichinio‘chirish. (270USA-10002). 29. Poz.Н270001 tuzlarini eritish pechida maksimal haroratda (≥4400C) bo‘lganda poz.BG270001 yoqgichini o‘chirish (tabiiy gaz ta’minoti 270TV-10016 qopqoqni va 270TV-10017 o‘choqqa havo yetkazib berishni yopish)(270TIСSAH,HH-10024). 30. Poz.Н270001 tuzlarini eritish pechidagi ichki zmeyevikni (250°C) minimal haroratida poz.Р270011eritilgan tuz nasosini ishga tushirish uchun ruxsat (270TISAL,LL-10025А). 31. Poz.Н270001 tuzlarini eritish pechidagi ichki zmeyevikni (≥220°C) minimal haroratida poz.Р270011 eritilgan tuz nasosini ishga tushirish uchun ruxsat (270TISAL,LL-10025В). 32. Poz.V270009 eritilgan tuz rezervuaridagi eritilgan tuzning minimal haroratida (190 0C) poz.P270011 eritilgan tuz nasosini ishga tushirish uchun ruxsat (270TISAL,LL-10027). 33. Poz.V270008 tuzsizlangan suvning aylanma bakidagi minimal darajada (≤ 10 %)bo‘lganda poz.P270010AB nasosini o‘chirish (270LISAL,LL-12001). 34. Poz.P2700016 suyultirilgan ishqor nasosining ishlamay qolishi.Nasosning favqulodda to‘xtash signalizatsiyasi. Nasos to‘xtaganda poz.BG270001 yoqgichini o‘chirish. (270USA-12003). 4.3.7 Rezervuarlar parki va tayyor mahsulotlar ombori (209-bino) 1. Poz.V290001AB 50%li kaustik soda rezervuarlarida (500 mm) minimal darajada poz.P290001ABC nasoslarini o‘chirish (290LISAH,HHL,LL-01001AC). 2. 50% li kaustik sodasini temir yo‘l transportiga maksimal darajaga yetganda yuklashni to‘xtatish (290XV-01001A-F klapanlarining yopilishi) (290LSH-01003A-F). 3. 50% li kaustik sodasini avtomobil transportiga maksimal darajaga yetganda yuklashni to‘xtatish (290XV-01001G chiqib ketish klapanini yopish) (290LSH-01003G). 4. Poz.V290003AB xlorid kislota rezervuarlarida (500 mm) minimal darajada poz.P290003 nasosini o‘chirish (290LISAH,HHL,LL-02001AB). 5. Xlorid kislotasini avtomobil transportiga maksimal darajaga yetganda yuklashni to‘xtatish (290XV-02001klapanini yopish) (290LSH-02004). 6. Poz.V290004 natriy gipoxlorid rezervuari (500 mm) minimal darajada poz.P290004 nasosni o‘chirish (290LISAH,HHL,LL-02005). 7. Natriy gipoxloritni avtomobil transportiga maksimal darajaga yetganda yuklashni to‘xtatish (290XV-02002 chiqib ketish klapanini yopish) (290LSH-02006). 8. Poz.V290005 32% kaustik soda saqlash rezervuarida (500 mm) minimal darajada poz.P290005AB nasoslarini o‘chirish (290LISAH,HHL,LL-03001). 9. Poz.V290002 konsentrlangan sulfat kislotani saqlash rezervuarida (500 mm) minimal darajada poz.P290002 nasosini o‘chirish (290LISAH,HHL,LL-03004). 10. Poz.V290008 issiq suv rezervuarida minimal darajada poz.P290006AB nasoslarini o‘chirish (290LISAH,HHL,LL-04001). Download 0.92 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling