- Table 2-8 Brief Technical Information of Selected Turbine I TEM U NIT E NVISION
- Pitch System
G
RID C ONNECTION Each wind turbine will be provided with one transformer to connect with grid. The power transmission circuit will be connected with the low voltage side of transformers via a main switch for incoming line and directly buried cables. During the start-up and grid connection process of the wind turbine, the wind direction sensor will detect the wind direction and enables the yaw controller to actuate, aligning the wind turbine with wind direction. When wind speed exceeds cut-in wind speed, the wind turbine output voltage is adjusted to the value of grid voltage and the system frequency is made suitable for grid connection through the control of full power converter. At the same time, the phase difference between grid voltage and generator's terminal voltage is measured. When such difference becomes zero (zero crossing point), the power element of the converter, operates to achieve grid connection (all these actions in EN171.6.5 wind turbine can be realized through converter system). Other components of the wind turbine will include: Lightning protection and grounding; Environmental control system; Monitoring system; Automatic fire protection system; A brief technical information of the selected turbine is provided in the table below. Dzhankeldy 500MW Wind Farm ESIA Volume 2- Main Text, Tables & Figures 58 Table 2-8 Brief Technical Information of Selected Turbine I TEM U NIT E NVISION 171 6.5MW Basic data of Wind Turbine Manufacturer/model Envision EN 171/6.5 Rated Power kW 6500 Rotor Diameter m 171 Hub Height m 100 Cut-in Wind Speed (10 minutes) m/s 3 Rated Wind Speed (10 minutes) m/s 12.8 Cut-out Wind Speed m/s 25 Maximum Wind Speed (10min average) m/s 42.5 Operating Temperature Range o C Normal atmospheric temperature wind turbine :-10°C to 40°C Survival Temperature Range o C -20°C to 50°C Design Service Life Year 20 Blade Number of blades - 3 Blade length m 83.9 Weight t 20.5 Blade Material Glass fiber reinforced polymer (GFRP) Blade Processing Technology - Vacuum infusion Blade Root Connection - Metal flange Swept Area of Rotor m 2 22965 Pitch System Pitch control - Electric pitch control Pitch range - -5 o ~ 90 o Type of backup power supply for pitch control - Supercapacitor Maximum speed of pitch motor rpm 2500 Type of pitch motor - AC Permanent Magnet Synchro (PMS) Pitch lubrication - Automatic lubrication Download 6.64 Mb. Do'stlaringiz bilan baham: |
Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©fayllar.org 2024
ma'muriyatiga murojaat qiling
ma'muriyatiga murojaat qiling